LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace

Pagina creata da Pietro Rizzi
 
CONTINUA A LEGGERE
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
Maggio May 2021

LA RISTRUTTURAZIONE DI
PALAZZO ROCCABONELLA
DAL RILIEVO LASER SCANNER AL MODELLO BIM INTEGRATO

The renovation of Roccabonella palace
From laser scanner survey to integrated bim model
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
2 PALAZZO ROCCABONELLA

                             LA RISTRUTTURAZIONE DI
                             PALAZZO ROCCABONELLA
                             DAL RILIEVO LASER SCANNER AL MODELLO BIM INTEGRATO

                             The renovation of Roccabonella palace
                             From laser scanner survey to integrated bim model

                         1. LA STORIA HISTORY                                                     4
                         2. IL PROGETTO ABOUT THE PROJECT                                         6
                         3. RILEVAZIONE METRICA DELL’EDIFICIO BUILDING METRIC SURVEY              8
                              Rilievo topografico Topographic survey                              8
                              Rilievo Laser Scanner 3D 3D Laser Scanner Survey                    8
                              Unione e ottimizzazione del dato di rilievo                         10
                              Union and optimisation of the survey data
                         4. LA RESTITUZIONE DEL RILIEVO RESTITUTION OF THE SURVEY                 12
                              Restituzione della nuvola di punti Point cloud return               12
                              Restituzione dello stato di fatto Restitution of the actual state   14
                              Confronto rilievo con stato di progetto                             14
                              Comparison of the survey with the project status
                         5. LA MODELLAZIONE BIM BIM MODELLING                                     16
                              Impostazione dei modelli Setting up models                          16
                              Impostazione dei livelli di riferimento Setting Reference Levels    18
                              Assegnazione delle WBS Assigning WBSs                               20
                              Utilizzo di Dynamo Using Dynamo                                     20
                         6. LA PROGETTAZIONE ARCHITETTONICA ARCHITECTURAL DESIGN                  24
                              Criteri di progettazione Design criteria                            24
                              Verifica dei requisiti normativi Checking regulatory requirements   24
                              Codifica degli elementi Coding of elements                          24
                         7. LA PROGETTAZIONE IMPIANTI SYSTEM DESIGN                               26
                              Criteri di progettazione Design criteria                            26
                              Impianti meccanici Mechanical system                                28
                              Impianti elettrici Electrical system                                28
                         8. IL BIM 5D – LA COMPUTAZIONE INTEGRATA INTEGRATED COMPUTATION          30
                               Criteri generali General Criteria                                  30
                               Applicazione alla modellazione Application to Modelling            32
                               Finiture Finishing                                                 34
                               Controsoffitti, pareti e contropareti in cartongesso               34
                               Plasterboard ceilings, walls and counter walls
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
4 PALAZZO ROCCABONELLA                                                                                 ROCCABONELLA PALACE 5

  1          La storia
             History

  Lo straordinario “Palazzo Roccabonella”, situato nel centro
  storico di Padova lungo via S. Francesco, a due passi dalle
  principali piazze cittadin, risale - secondo le stime - alla fine del
  ‘400.
  È considerato uno dei più preziosi e suggestivi edifici del
  patrimonio architettonico padovano.
  In origine fu la residenza del medico e filosofo veneziano
  Pietro Roccabonella, mentre dalla chiusura del primo
  ventennio del ‘500 fino alla fine del secolo fu dimora di
  Antonio da Passano, per poi essere ceduto nelle mani di
  Roberto di Marsilio Papafava.
  Nel 1700, al palazzo venne aggiunta un’ala del prospetto
  d’ordine rustico, forse su progetto dell’architetto Girolamo
  Frigimelica.
  Grazie alle attente analisi dell’Architetto Albano Salmaso, alla
  sapienza ingegneristica di INCIDE, alla cura dello sviluppatore
  Patavium, e dell’impresa Carron, che ne ha curato i lavori di
  restauro, Palazzo Rocabonella è stato accompagnato verso
  la sua nuova vita ed attende di accogliere persone capaci di
  comprenderne l’essenza, la qualità, l’energia positiva.

  The extraordinary ‘Palazzo Roccabonella’, located in the historic       Palazzo Roccabonella -
  centre of Padua along Via S. Francesco, a stone’s throw from the        Padova | Via San Francesco
  main city squares, dates back - according to estimates - to the
  end of the 15th century.
  It is considered one of the most precious and evocative buildings
  of Padua’s architectural heritage.
  It was originally the residence of the Venetian physician and
  philosopher Pietro Roccabonella, while from the end of the first
  twenty years of the 16th century until the end of the century it
  was the home of Antonio da Passano, before being handed over
  to Roberto di Marsilio Papafava.
  In the 18th century , a wing of the rustic order elevation was
  added to the palace, possibly to a design by architect Girolamo
  Frigimelica.
  Thanks to the careful analysis of Architect Albano Salmaso,
  the engineering expertise of INCIDE, the care of the developer
  Patavium, and the Carron company, which oversaw the
  restoration work, Palazzo Rocabonella has been guided
  towards its new life and is waiting to welcome people capable of
  understanding its essence, quality and positive energy.
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
6 PALAZZO ROCCABONELLA                                                                                                                                                                                                     ROCCABONELLA PALACE 7

  2          Il Progetto
             About the Project

                                                                                                       © Incide Enginneering
  Il Palazzo Roccabonella-Papafava,                                                                                                                  Palazzo Roccabonella-Papafava, a 16th-        finally the “Contemporaneo” block.
  edificio cinquecentesco di pregio                                                                                                                  century building of historical value, which   The Roccabonella project is an example of in-
  storico che dà il nome al complesso,                                                                                                               gives its name to the complex, has been       tegrated design, in the sense that it combines:
  è stato oggetto nei secoli di aggiunte                                                                                                             the subject of additions and revisions
  e rivisitazioni che hanno portato alla                                                                                                             over the centuries, leading to its current    • The most up-to-date and precise
  situazione odierna, dove i fabbricati,                                                                                                             situation, where the buildings, grouped       technologies for the survey, analysis,
  aggregati tra loro, abbracciano                                                                                                                    together, embrace the inner corner of a       design of the site.
  l’interno angolo di un isolato e                                                                                                                   block and form a private courtyard.
  formano al loro interno una corte                                                                                                                  The urban aggregate has been divided          • The choice of the most advanced
  privata. L’aggregato urbano è stato                                                                                                                into blocks according to the time of          solutions to guarantee physical well-
  suddiviso in blocchi secondo l’epoca                                                                                                               construction and the nature of the            being.
  di costruzione e la natura degli edifici.                                                                                                          buildings. We can therefore identify the
  Si possono identificare quindi i blocchi                                                                                                           “Roccabonella” and “Ala Ovest” (west wing     • A holistic approach to ensuring
  “Roccabonella” e “Ala Ovest”, datati ad                                                                                                            )blocks, dating back to the early 16th        people’s well-being.
  inizio ‘500 e caratterizzati da ampi saloni                                                                                                        century and characterised by large halls
  e particolari artistici di pregio, il blocco                                                                                                       and fine artistic details, the “Ottocento”    • Perfect interdisciplinary
  “Ottocento”, che occupa l’angolo tra                                                                                                               block, which occupies the corner              coordination.
  via S. Francesco e vicolo S. Margherita,                                                                                                           between Via S. Francesco and Vicolo S.
  il blocco “Transizione”, collegamento                                                                                                              Margherita, the “Transizione” block, a        All this to give shape to a project
  successivo del Palazzo e dell’edificio                                                                                                             later link between the Palazzo and the        involving 30 residential units, 2
  ottocentesco, il blocco “Ventennio”,                                                                                                               19th-century building, the “Ventennio”        commercial premises and 49 garages.
  risalente agli ’20 del Novecento, ed                                                                                                               block, dating back to the 1920s, and
  infine il blocco “Contemporaneo”.
                                                                                                                               ©Incide Engineering
  L’intervento in Roccabonella è un              Incide è stata incaricata della   Incide was entrusted with the
  esempio di progettazione integrata, nel        Progettazione Architettonica      Executive Architectural Design,
  senso che esso abbina:                         Esecutiva, degli interventi       Structural Adjustment and
                                                 di adeguamento Strutturale        Integrated Plant Design, with
  • Le tecnologie più attuali e precise          e della progettazione             BIM methodologies, applied not
  per il rilievo, l’analisi, la progettazione    Impiantistica integrata,          only to the design phase, but
                                                 con metodologie BIM,              also to the construction phase
  del luogo.
                                                 applicate non solo alla fase      with 4D and 5D applications.
                                                 progettuale, ma anche alla
  • La scelta delle soluzioni più evolute
                                                 fase di cantierizzazione con
  per garantire il benessere fisico.
                                                 applicazioni 4D e 5D.

  • Un approccio olistico rivolto ad
  assicurare il benessere delle persone.

  • Un perfetto coordinamento
  interdisciplinare.

  Tutto questo, per dare forma ad
  un intervento che prevede 30 unità
  abitative, 2 locali a uso commerciale e
  49 garage.
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
8 PALAZZO ROCCABONELLA                                                                                                                                                                                                                    ROCCABONELLA PALACE 9

  3           Rilevazione metrica dell’edificio
              Building metric survey
              Verificazione dello stato di fatto dell’edificio
              Verification of the state of the building

  Rilievo Laserscanner                           definizione di una rete plano-altimetrica     scansione (architettura, morfologia
  Il primo passo è stato effettuare              finalizzata ad inquadrare tutte le            del terreno, vegetazione, ecc..). Come
  un rilievo per verificare lo stato             successive operazioni di acquisizione         risultato si ottiene una nuvola di
  dei luoghi e la sua conformità con             dei dati. Tale inquadramento è                punti tridimensionale (di ogni punto
  la documentazione fornita. Data                stato calcolato in valore relativo            acquisito conosciamo le coordinate
  la dimensione e la complessità                 rispetto a due punti di coordinate ed         spaziali XYZ e il colore RGB), in grado di
  dell’aggregato si è scelto di procedere        orientamento noto, al fine di facilitare      riprodurre esattamente lo stato di fatto
  con metodologia di rilievo Laser               le successive fasi di modellazione e          dell’oggetto analizzato e consentendo
  Scanner 3D. Il rilievo è stato fatto da        progettazione.                                la successiva discretizzazione
  specialisti del settore con l’ausilio di                                                     e rappresentazione in formati
  una stazione totale Leica TS13 per             Rilievo Laser scanner 3D                      bidimensionali e tridimensionali
  la topografia di supporto e da Laser           Il rilievo Laser Scanner 3D consiste
  Scanner Leica BLK360 per le scansioni          nell’acquisizione di dati metrici e assetti
  laser 3D                                       deformati per mezzo di un apparato
                                                 di rilevamento a raggi laser; in questo
  Rilievo Topografico                            caso si tratta di laser scanner 3D del
  L’inquadramento topografico                    tipo distanziometrico, il cui sensore
  costituisce la fase preliminare a tutte        di scansione opera registrando tutti
  le attività di rilievo e consente la           i punti visibili rispetto al centro di

                                                                                                                                             Laser scanner survey                          to two points of known coordinates
                                                                                                                                             The first step was to carry out a survey      and orientation, in order to facilitate
                                                                                                                                             to verify the state of the sites and its      the subsequent modelling and design
                                                                                                                                             conformity with the documentation             phases.
                                                                                                                                             provided. Given Due to the size and
                                                                                                                                             complexity of the aggregate, it was           3D Laser Scanner Survey
                                                                                                                                             decided to proceed with a 3D Laser            The 3D Laser Scanner survey consists
                                                                                                                                             Scanner survey methodology. The survey        in the acquisition of metric data and
                                                                                                                                             was carried out by specialists in the field   deformed structures by means of a laser
                                                                                                                                             with the aid of a Leica TS13 total station    survey apparatus; in this case it is a 3D
                                                                                                                                             for the supporting topography and a           laser scanner of the distance type, whose
                                                                                                                                             Leica BLK360 Laser Scanner for the 3D         scanning sensor operates by recording
                                                                                                                                             laser scanning.                               all visible points with respect to the
                                                                                                                                                                                           scanning centre (architecture, ground
                                                                                                                                             Topographic survey                            morphology, vegetation, etc.). As a result,
              Cattura Capture                               Elabora Process                               Progetta Design
                                                                                                                                             The topographical survey is the               a three-dimensional point cloud is obtained
                                                                                                                                             preliminary phase to all the survey           (the XYZ spatial coordinates and RGB colour
  Nuvole di punti da       Point clouds from     Registrazione          Automatic recording    Creazione DTM        DTM creation
                                                                                                                                             activities and allows the definition          of each point acquired are known), capable
  laser scanner a terra    laser scanner on      automatica             Cleaning editing       integrazione nel     integration in the BIM
  o da drone o aereo.      the ground or from    Pulizia editing e      and georeferencing     processo BIM         process                  of a plano-altimetric network aimed           of reproducing the exact state of affairs
  Foto digitali da terra   drone or plane.       georeferenziazione     3D meshes and                                                        at framing all the subsequent data            of the object being analysed and allowing
  o da drone.              Digital photos from   Mesh 3D ed ortofoto    orthophotos from                                                     acquisition operations. This survey was       subsequent discretisation and representation
                           ground or drone.      da nuvole di punti e   point clouds and                                                     calculated in relative value with respect     in two- and three-dimensional formats.
                                                 foto digitali.         digital photos.
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
10 PALAZZO ROCCABONELLA                                                                                                                                                                             ROCCABONELLA PALACE 11

  3
  Unione e ottimizzazione del dato di rilievo                                                                                                    Union and optimisation of survey data
  In questa fase sono stati utilizzati i       ► Diverse visualizzazioni della nuvola di punti sul visualizzatore. Dall’ alto: visualizzazione                                In this phase the Leica BLK360 software
  software Leica BLK360, che in con-           nuvola in scala di grigi; visualizzazione nuvola per intensità dei punti. Le piramidi gialle                                   was used, which in connection with the
  nessione con il sistema di scansione         indicano le postazioni di rilevazione e permettono la visualizzazione panoramica della                                         scanning system allows the acquisition
                                               nuvola da quel punto.
  permette l’acquisizione e il primo alline-                                                                                                                                  and the first alignment and Leica Cyclone
                                               Different views of the point cloud on the viewer. From top: cloud view in grey scale; cloud
  amento in campagna, e Leica Cyclone                                                                                                                                         Register 360, software for the mana-
                                               view by intensity of points. The yellow pyramids indicate the surveying locations and allow
  Register 360, software di gestione,                                                                                                                                         gement, union and optimisation of the
                                               a panoramic view of the cloud from that point.
  unione e ottimizzazioni del dato nuvola                                                                                                                                     point cloud data, which allows the control
  di punti, che permette di fare opera-                                                                                                                                       and discretization of the survey data. In
  zioni di controllo e discretizzazione del                                                                                                                                   this specific case, for a better manage-
  dato rilevato. Nel caso specifico, per                                                                                                                                      ment of the data itself, the survey was
  una miglior gestione del dato stesso, il                                                                                                                                    subdivided as shown below:
  rilievo è stato suddiviso come di seguito
  riportato:                                                                                                                                                                  • Building ABCD (including the Roccabo-
                                                                                                                                                                              nella, West Wing, Transition and Ottocen-
  • Blocco ABCD (comprendente gli edifici                                                                                                                                     to buildings)
  Roccabonella, Ala Ovest, Transizione e                                                                                                                                      • Building H (including the two basement
  Ottocento).                                                                                                                                                                 floors in the internal courtyard)
  • Blocco H (comprendente i due piani                                                                                                                                        • Building GEF (including the Ventennio
  interrati nella corte interna).                                                                                                                                             and Contemporaneo buildings)
  • Blocco GEF (comprendente gli edifici                                                                                                                                      • OUTDOOR.
  Ventennio e Contemporaneo)
  • Blocco ESTERNI.                                                                                                                                                           This made it possible to export the above
                                               © Incide Enginneering
                                                                                                                                                                              partition sections in the E57 format,
  Questo ha permesso di esportare le so-                                                                                                                                      in order to be “indexed” by Autodesk
  pracitate partizioni nel formato E57, per                                                                                                                                   RecapPro in the RCP format, in order to
  poter essere “indicizzate” da Autodesk                                                                                                                                      create a database to be managed within
  RecapPro nel formato RCP, al fine di                                                                                                                                        the Autodesk Revit modelling software.
  creare un database per essere gestito
  all’interno del software di modellazione                                                                                                                                    The Leica Jet Stream Viewer was particu-
  Autodesk Revit.                                                                                                                                                             larly useful for consulting the point cloud
                                                                                                                                                                              (total size of the 4 blocks in RCP format is
  Particolarmente utile per la consulta-                                                                                                                                      about 400 Giga). Working on files in LGS
  zione della nuvola di punti (dimensione                                                                                                                                     format that are much lighter than the
  complessiva dei 4 blocchi in formato                                                                                                                                        corresponding RCP files (total size of the
  RCP di circa 400Giga) è stato il visua-                                                                                                                                     4 blocks in LGS format is about 40 Giga),
  lizzatore Leica Jet Stream Viewer, che                                                                                                                                      the Leica Jet Stream Viewer allowed
  lavorando su file in formato LGS molto                                                                                                                                      the entire project team, even those not
  più leggeri dei corrispettivi RCP (di-                                                                                                                                      equipped with modelling software, to
  mensione complessiva dei 4 blocchi in                                                                                                                                       consult the cloud if necessary.
  formato LGS circa 40Giga) ha permesso
  alla totalità del team di progetto, anche
  chi non dotato dei software di model-
  lazione, di consultare all’occorrenza la
  nuvola.
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
12 PALAZZO ROCCABONELLA                                                                                                                                       ROCCABONELLA PALACE 13

  4          La restituzione del rilievo
             Restitution of the survey

  Restituzione della                                                                        Point cloud return                           inter-floor heights, was flanked by the
                                                                                                                                         photographic survey and the on-site in-
  nuvola di punti                                                                           Once the Laser Scanner survey had been
                                                                                                                                         spection, to gather information about the
  Una volta effettuato il rilievo Laser                                                     carried out, the resulting point cloud
                                                                                                                                         materials used and any peculiarities, and
  Scanner, indicizzata la nuvola di punti                                                   indexed and framed in the correct posi-
                                                                                                                                         the documentation relating to the work
  risultante e inquadrata questa nella po-                                                  tion in space, it was possible to connect
                                                                                                                                         carried out previously, useful above all
  sizione corretta nello spazio, si è potuto                                                it directly in its RCP format to the Revit
                                                                                                                                         for the nature of the existing floors and
  collegarla direttamente nel suo formato                                                   model, proceeding with the restitution of
                                                                                                                                         the underground elements.
  RCP al modello Revit, procedendo con                                                      the survey.
                                                                                                                                         On this specific occasion, no particular
  la restituzione del rilievo.
                                                                                                                                         attention was paid to the restitution of
                                                                                            The cloud survey is then sectioned, both
                                                                                                                                         the decorative architectural details, such
  La nuvola viene così sezionata, sia in                                                    in plan and in elevation, and traced with
                                                                                                                                         as cornices, capitals and friezes, since
  pianta che in elevazione, e ricalcata con                                                 the objects of the modelling software.
                                                                                                                                         they were the subject of specific restora-
  gli oggetti propri del software di mo-                                                    This procedure, which made it possible
                                                                                                                                         tion work, already carried out externally
  dellazione. A questo procedimento, che                                                    to extrapolate the thickness of the walls,
                                                                                                                                         and identified internally.
  ha permesso di estrapolare gli spessori                                                   the dimensions of the openings and the
  dei muri, le dimensioni delle aperture
  e le altezze interpiano, si è affiancato il
  rilievo fotografico e l’ispezione in situ,
  per raccogliere informazioni circa i
  materiali utilizzati ed eventuali peculia-
  rità, e la documentazione relativa agli
  interventi precedentemente realizzati,
  utile soprattutto per la natura dei solai
  esistenti e degli elementi interrati.
  In questa specifica occasione non si è
  data particolare attenzione alla restitu-
  zione dei dettagli architettonici deco-
  rativi, quali cornicioni, capitelli e fregi,
  poiché oggetto di specifici interventi
  di restauro, già effettuati all’esterno e
  identificati all’interno.

  ►In rosso la nuvola di punti sezionata, in     ▲ Sovrapposizione del modello 3D con la
  nero gli elementi di modellazione              nuvola di punti rilevata
  In red the sectioned point cloud survey, in    Superimposition of the 3D model with the
  black the modelling elements.                  detected point cloud
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
14 PALAZZO ROCCABONELLA                                                                                                                       ROCCABONELLA PALACE 15

  4
  Restituzione dello stato di                   Restitution of the existing                    ► Sovrapposizione del modello 3D con la
                                                                                               nuvola di punti rilevata. In rosso la nuvola
  fatto                                         state                                          di punti sezionata, in nero gli elementi di
  L’attenzione è posta sulla spazialità         The focus is on the internal space rather      modellazione
  interna più che sull’involucro esterno,       than on the external , which is already        Superimposition of the 3D model with the
  già oggetto di interventi:                    the subject of interventions:                  detected point cloud. In red the sectioned
  • vengono verificate le quote interne al      • the internal raw heights and the in-         point cloud survey, in black the modelling
  grezzo e le altezze interpiano, essen-        ter-floor heights are checked, which are       elements.
  ziali per la progettazione di soppalchi e     essential for the design of lofts and attic
  locali sottotetto;                            rooms;
  • vengono rilevate la tipologia e lo          • the type and thickness of the walls
  spessore delle murature, identificando        are surveyed, identifying any previously
  eventuali aperture precedentemente            walled openings that may be useful in
  murate che possono risultare utili in         the design phase, for example for the
  fase di progetto, ad esempio per pas-         passage of systems;
  saggio impianti;                              • the position, size and height of the thre-
  • viene verificata la posizione, la di-       shold of external openings are checked,
  mensione e l’altezza della soglia delle       in view of the design of the windows and
  aperture esterne, in vista della proget-      doors;
  tazione dei serramenti;                       • any discrepancies between the structu-
  • vengono rilevate eventuali discrepan-       ral design received and the actual
  ze tra il progetto strutturale pervenuto      construction are detected, as well as the
  e l’effettiva realizzazione, così come la     verification of floor thicknesses, position
  verifica di spessori solai, posizione e       and type of floor beams and lofts.
  tipologia delle travi di solaio e soppalco.   The result is a relatively slim model
  Il risultato è quindi un modello rela-        that already contains all the basic
  tivamente snello che però contiene            dimensional and typological infor-
  già tutte le informazioni dimensio-           mation needed as a starting point
  nali e tipologiche di base necessa-           for the design.
  rie come punto di partenza per la
  progettazione.

  Confronto rilievo con stato                   Comparison of the survey
  di progetto                                   with the project status
  Una volta completata la restituzione si è     Once the restitution was completed, the
  comparata la geometria ottenuta con i         geometry obtained was compared with
  disegni di progetto esistenti per vedere      the existing design drawings to see and
  e compensare eventuali discrepanze. La        compensate for any discrepancies. The
  sovrapposizione è risultata pressoché         overlapping was almost exact for the
  esatta per quanto riguarda il piano ter-      ground floor, diverging more as it goes
  ra, andando a divergere maggiormente          up towards the top floor. Although in the
  salendo verso l’ultimo piano. Sebbene         worst cases the difference was as much
  nei casi peggiori la differenza arrivasse     as 30-40cm, adjustments to the design
  anche a 30-40cm, gli aggiustamenti al         were minimal and localised.
  progetto sono stati minimi e localizzati.
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
16 PALAZZO ROCCABONELLA                                                                                                                                                                              ROCCABONELLA PALACE 17

  5          La modellazione BIM
             Bim modelling

  La metodologia BIM nasce nel contesto di edifici di nuova costruzione ma soprattutto                  La suddivisione e relativa codifica   The subdivision and relative coding are
  negli ultimi anni l’attenzione della filiera delle costruzioni si è spostata verso l’esistente        risultano quindi le seguenti:         as follows:
  e chiede l’applicazione dei vantaggi di tale metodologia a fabbricati esistenti e spesso di
  valore storico-artistico, patrimonio di cui il nostro paese non è di certo povero. In questi          • AO – Ala ovest                      - AO - West Wing
  casi si parla di HBIM, ovvero di “Historic Building Information Modelling”, indicando con             • RC – Roccabonella                   - RC - Roccabonella
  questo termine un procedimento di modellazione geometrica e d’informazione molto                      • TR – Transizione                    - TR - Transition
  accurato, in cui gli edifici vengono rilevati da strumenti di precisione come i laser scanner         • OT – Ottocento                      - OT - Nineteenth century
  e riportati in nuvole di punti, per poi essere comparati a librerie di oggetti parametrici che        • VE – Ventennio (suddiviso           - VE - Ventennio (internally subdivided
  vengono sovrapposti alla nuvola finché non si raggiunge una somiglianza soddisfacente.                internamente in V1 e V2)              into V1 and V2)
  In questa applicazione specifica, è risultato particolarmente importante sviluppare un                • CN – Contemporaneo                  - CN - Contemporary
  modello ben organizzato e catalogato, integrato nel processo di computazione, che sappia              • NI – Nuovi interrati                - NI - New basements
  dialogare con la molteplicità di figure che interagiscono in un cantiere di questa natura,
  pur mantenendo una sua coerenza e solidità.

  Impostazione dei modelli                                                                                                                         RC
  La fase iniziale di organizzazione e impostazione del modello BIM assume un’importanza
  fondamentale che sarà strategica per tutta la durata della progettazione. Si è scelto di
  suddividere l’aggregato negli edifici che lo compongono, realizzando un modello per
  fabbricato, coordinati tra loro da un modello federativo, depositario delle coordinate
  condivise generali e dei livelli di tutti i fabbricati.                                                                                                                                                        A0
                                                                                                                                  TR

  The BIM methodology was born in the context of new buildings, but especially in recent years
  the attention of the construction industry has shifted towards existing buildings and calls                   OT
  for the application of the advantages of this methodology to existing buildings and often
  of historical-artistic value, a heritage of which our country is certainly not lacking. In these
  cases we speak of HBIM, or “Historic Building Information Modelling”, indicating with this
  term a very accurate geometric and information modelling procedure, in which buildings are
  surveyed by precision instruments such as laser scanners and reported in point clouds, and
  then compared to libraries of parametric objects that are superimposed on the cloud until a
  satisfactory similarity is achieved. In this specific application, it was particularly important to
  develop a well-organised and catalogued model, integrated in the computation process, which
  is able to dialogue with the multiplicity of figures that interact on a site of this nature, while
  maintaining its own coherence and solidity.

  Setting up models
  The initial phase of organising and setting up the BIM model is of fundamental importance and
  will be strategic throughout the design process. It was decided to divide the aggregate into                                    VE
  its component buildings, creating one model per building, coordinated by a federative model,
  which is the depository of the general shared coordinates and levels of all the buildings.
                                                                                                                                                                                        CN

                                                                                                                                                                                        ©®Ximi, ut eum et quasim - Gianluca Vallerini
LA RISTRUTTURAZIONE DI PALAZZO ROCCABONELLA - The renovation of Roccabonella palace
18 PALAZZO ROCCABONELLA                                                                                                                                                                                                                                       ROCCABONELLA PALACE 19

  5
  Impostazione dei livelli di riferimento                                                                                                 Setting reference levels
  Un passo importante nell’impostazione         e il diametro del tubo.                    re in considerazione l’uso che verrà           An important step in the initial setting      floor (I02, I01, L0, L1, L2), also distingui-   coded as ACS (hot sanitary water), I will
  iniziale dei modelli è poi la definizione     Avere una serie di template “pronti        fatto di questi modelli, quante e quali        up of the models is then the definition       shing whether it is the main floor (P) or       see on my view already the pink colour
  dei livelli di riferimento, che faranno da    all’uso”, impostati già secondo lo         informazioni vogliamo siano subito             of the reference levels, which will be        the mezzanine floor that will be added in       assigned to the specific circuit and I will
  base per tutti gli oggetti che verranno       standard grafico aziendale e secondo       percepite dalla codifica, impostare una        the basis for all the objects that will be    the design phase (S).                           already find the appropriate label that
  creati. La storia e l’evoluzione di questo    la disciplina di progetto è un aiuto       convenzione efficace per eventuali             created. Over the centuries, the history                                                      will show me the system, the material
  aggregato ha portato nei secoli ad uno        importante per cominciare qualsiasi        abbreviazioni etc. La codifica degli           and evolution of this aggregate has led                                                       and the diameter of the pipe.
                                                                                                                                                                                        Until now we have created and codified
  sviluppo altimetrico non omogeneo,            progetto BIM con il piede giusto.          oggetti verrà trattata più approfondita-       to uneven height development, with the                                                        Having a set of “ready to use” tem-
                                                                                                                                                                                        the models, we have set the reference le-
  con il risultato che i piani dei diversi                                                 mente nei capitoli dedicati alle singole       result that the floors of the various buil-                                                   plates, already set up according to
                                                                                                                                                                                        vels and the shared coordinates, we have
  edifici non risultano mai allineati tra di                                               discipline, in particolare per la disciplina   dings are never aligned with each other,                                                      the company’s graphic standard and
                                                Un ulteriore passo importante per ini-                                                                                                  linked the models together according to
  loro, e molto spesso nemmeno all’in-                                                     architettonica, in cui tale impostazione       and very often not even within the same                                                       according to the project discipline is
                                                ziare un progetto è definire la codifica                                                                                                these coordinates and levels, we have
  terno dello stesso fabbricato. Da qui                                                    risulta determinante per il dialogo con il     building. Hence the decision to set the                                                       an important help to start any BIM
                                                degli oggetti. Tale codifica deve tene-                                                                                                 created for each model and discipline the
  la scelta di impostare i livelli suddivisi                                               software di computazione                       levels subdivided by building, choosing                                                       project on the right foot.
                                                                                                                                                                                        worksets that we are going to use, and
  per edificio, scegliendo come riferimen-                                                                                                as a reference the height at the finished
                                                                                                                                                                                        all this is done on the basis of templates
  to la quota al finito architettonico da                                                                                                 architectural design most common in
                                                                                                                                                                                        divided by discipline, already consolida-       A further important step in starting a
  progetto più diffusa in quella porzione.                                                                                                that portion. In the case of the Ventennio
                                                                                                                                                                                        ted within the practice of the studio. The      project is to define the coding of the
  Nel caso del Ventennio è stato neces-                                                                                                   it was necessary to further subdivide the
                                                                                                                                                                                        internally standardized templates already       objects. This coding must take into ac-
  sario suddividere ulteriormente i livelli                                                                                               levels between V1 and V2 because of the
                                                                                                                                                                                        contain many settings and information           count the use that will be made of these
  tra V1 e V2 a causa della considerevole                                                                                                 considerable difference in height.
                                                                                                                                                                                        typical of the discipline, for example the      models, how much and what information
  differenza di quota.
                                                                                                                                                                                        template “Mechanical” already contains          we want to be immediately perceived by
                                                                                                                                          The coding chosen therefore stems from        the piping systems that I’m going to use        the coding, set up an effective conven-
  Fino ad ora abbiamo creato e codificato                                                                                                 the need to identify first of all the refe-   and their graphic settings, so that when        tion for any abbreviations etc. The coding
  i modelli, abbiamo impostato i livelli di                                                                                               rence building (NI, AO, etc.) and then the    I’m going to model a multilayer pipe            of objects will be dealt with in more
  riferimento e le coordinate condivise,                                                                                                                                                                                                detail in the chapters dedicated to the
  abbiamo collegato i modelli tra loro                                                                                                                                                                                                  individual disciplines, in particular for
  secondo queste coordinate e questi                                                                                                                                                                                                    the discipline of architecture, where this
  livelli, abbiamo creato per ogni modello                                                                                                                                                                                              approach is crucial for dialogue with the
  e disciplina i worksets che andremo                                                                                                                                                                                                   computation software
  ad utilizzare, e tutto questo viene fatto
  sulla base di template suddivisi per di-
  sciplina, già consolidati all’interno della
  pratica dello studio. I template stan-
  dardizzati internamente contengono
  già molte impostazioni e informazioni
  tipiche della disciplina caratterizzante,
  ad esempio il template “Meccanico”
  contiene già i sistemi di tubazioni che
  andrò ad utilizzare e le loro impostazio-
  ni grafiche, in modo che quando andrò
  a modellare una tubazione in multistra-                                                                                                                                                                                               ◄ Sezione longitudinale parallela a via S.
  to codificata come ACS (acqua calda                                                                                                                                                                                                   Francesco
  sanitaria), la vedrò sulla mia vista già                                                                                                                                                                                              Longitudinal section parallel to Via S.
  del colore rosa assegnato allo specifico                                                                                                                                                                                              Francesco.
  circuito e troverò già l’etichetta adatta                                                                                                                                                                                             .
  che mi mostrerà il sistema, il materiale
20 PALAZZO ROCCABONELLA                                                                                                                                                                                                                                           ROCCABONELLA PALACE 21

  5
  Assegnzione delle WBS                                                                                                                         Assignment of WBSs
  Le WBS (Work Breakdown Structure)            indicante il codice del locale, la desti-        Molti degli script Dynamo utilizzati            Assignment of WBSs
  sono uno strumento utile a suddividere       nazione d’uso e le finiture richieste.           hanno al loro interno dei nodi speciali,        WBSs (Work Breakdown Structures) are a
  analiticamente un progetto in parti più      Dall’altra parte quello che bisogna fare         chiamati Python Script, che permettono          useful tool for analytically breaking down
  elementari e facilmente gestibili. Il pro-   nei modelli è inserire i locali e codificarli    all’utente di creare delle istruzioni ad        a project into more elementary and easily
  getto viene scomposto gerarchicamen-         secondo lo standard stabilito. Il trasferi-      hoc utilizzando il linguaggio di pro-           manageable parts. The project is broken
  te in componenti con grado di dettaglio      mento di informazioni da questo foglio           grammazione Python, e consentono                down hierarchically into components
  sempre maggiore, finché non si arriva        Excel ai 7 modelli architettonici avviene        di risolvere in modo molto snello dei           with an increasing degree of detail until
  a descrivere univocamente il singolo         tramite l’uso di uno script in Dynamo            punti critici dello script. Dynamo è stato      the individual work to be carried out is
  lavoro da svolgere e ad attribuirvi la re-   che funziona circa così: per ogni locale         utilizzato nel progetto, oltre che per il       unambiguously described and executive
  sponsabilità esecutiva. Nel nostro caso      del modello, leggo il codice del locale          trasferimento di informazioni con Excel,        responsibility assigned. In our case, the
  la prima suddivisione riguarda l’Edificio    (es. A1.01), cerco questo codice nella           anche per la compilazione dei parame-           first subdivision concerns the Building in
  in cui l’oggetto si trova, seguito dalla     colonna Excel indicata, quando trovo             tri, come ad esempio la descrizione di          which the object is located, followed by
  Zona, il Livello e la Lavorazione.           la corrispondenza esatta scorro la riga          muri, pareti ed infissi ottenuta diretta-       the Zone, the Level and the Work.
  Ogni oggetto modellato viene identi-         e scrivo nel parametro Revit dei locali          mente dalla loro codifica, compilazione
                                                                                                                                                Each modelled object is identified
  ficato con le suddette WBS, a partire        “Tipo di finitura del muro” quello che           del codice univoco di ogni serramento
                                                                                                                                                with the aforementioned WBSs,
  dagli elementi esistenti allo stato          trovo nella colonna Excel “Pareti”, e così       in base alle WBS, composizione della
                                                                                                                                                starting from the existing elements
  di fatto (identificati con WBS_Zona          via per tutte le voci richieste.                 codifica delle tavole e stampa di queste
                                                                                                                                                in their current state (identified with
  =EX), fino alla singola presa elettrica                                                       con la nomenclatura corretta.
                                                                                                                                                WBS_Zone =EX), down to the single
  di un dato appartamento.                                                                                                                      electrical socket in a given flat

  Utilizzo di Dynamo                                                                                                                            Using Dynamo
  Un alleato importante nella gestione         ▼ Procedimento per la scrittura delle            ► Esempio modello architettonico federato
                                                                                                                                                An important ally in project management
  del progetto è il plug in di Revit Dyna-     finiture di pavimenti, soffitti, pareti e        suddiviso per WBS_Zona (da sinistra livello
                                               battiscopa da foglio Excel ai locali di Revit    0, livello 1, livello 2)                        is the Revit Dynamo plug-in. It is useful
  mo. Utile in questo caso non tanto nella     tramite script Dynamo                            Example federated architectural model           here not so much for actual modelling as
  modellazione vera e propria, ma nel          Procedure for writing floor, ceiling, wall and   divided by WBS_ZONE (from left level 0, level   for transferring information from Excel
  trasferimento di informazioni da fogli       skirting finishes from Excel sheet to Revit      1, level 2)                                     sheets to model objects, automating long
  Excel ad oggetti del modello, nell’auto-     rooms using Dynamo scripts
                                                                                                                                                and repetitive processes and controlling
  mazione di processi lunghi e ripetitivi e                                                                                                                                                  to be done in the templates is to enter        Scripts, which allow the user to create
                                                                                                                                                data.
  nel controllo dei dati.                                                                                                                                                                    the rooms and code them according to           ad hoc instructions using the Python
                                                                                                                                                An example of application may be the         the established standard. The transfer of      programming language, and allow critical
                                                                                                                                                initial compilation of the abacuses of       information from this Excel sheet to the 7     points in the script to be resolved in a
  Un esempio di applicazione può essere                                                                                                         room finishes: coverings, plasters, floors   architectural models takes place through       very streamlined way.
  la compilazione iniziale degli abachi                                                                                                         differ in macro-groups according to the      the use of a script in Dynamo that works       Dynamo was used in the project not only
  delle finiture dei locali: rivestimenti,                                                                                                      monumental, historical or contemporary       approximately as follows: for each room        for the transfer of information with Excel,
  intonaci, pavimenti si differiscono in                                                                                                        nature of the building in which the flat     in the model, I read the room code (e.g.       but also for the compilation of parame-
  macro-gruppi in base alla natura mo-                                                                                                          is located, or whether the unit under        A1.01), I look for this code in the Excel      ters, such as the description of walls, wal-
  numentale, storica o contemporanea                                                                                                            consideration is a shop or a gymnasium;      column indicated, when I find the exact        ls and frames obtained directly from their
  dell’edificio in cui l’appartamento si                                                                                                        they change if they are in living areas,     match I scroll the line and write in the       coding, compilation of the unique code
  sviluppa o se l’unità in esame è un ne-                                                                                                       sleeping areas or bathrooms, if they are     Revit parameter of the rooms “Type of          of each frame based on the WBS, com-
  gozio o una palestra, cambiano se sono                                                                                                        cellars, basements or mezzanines, and        wall finish” what I find in the Excel column   position of the coding of the tables and
  in zona giorno, zona notte o bagni, se                                                                                                        so on. All these indications are then sum-   “Walls”, and so on for all the items requi-    printing them with the correct nomencla-
  sono cantine, interrati o soppalchi, e via                                                                                                    marised and ordered in tabular form in       red.                                           ture. Procedure for writing floor, ceiling,
  dicendo. L’insieme di queste indica-                                                                                                          an Excel sheet, indicating the code of the
                                                                                                                                                                                             Many of the Dynamo scripts used have           wall and skirting finishes from Excel sheet
  zioni viene allora riassunto e ordinato                                                                                                       room, the intended use and the required
                                                                                                                                                                                             special nodes within them, called Python       to Revit rooms using Dynamo scripts
  in forma tabellare in un foglio Excel,                                                                                                        finishes. On the other hand, what needs
22 PALAZZO ROCCABONELLA                            ROCCABONELLA PALACE 23

  Render degli esterni di Palazzo Roccabonella
  Render of the exterior of Palazzo Roccabonella
24 PALAZZO ROCCABONELLA                                                                                                                                                                                                                                   ROCCABONELLA PALACE 25

  6          La progettazione architettonica
             Architectural design

  Criteri di progettazione                                                                                                           Design criteria                                 The spatial complexity of the site is a         Element coding
                                                                                                                                                                                     challenge for the design: buildings close
  La progettazione architettonica di                                                                                                 The architectural design of Roccabonella                                                        The coding of the elements was an
                                                                                                                                                                                     to but different from each other must
  Roccabonella si configura come                                                                                                     is a continuous search for balance                                                              important and necessary phase due to
                                                                                                                                                                                     dialogue harmoniously, architectural
  una continua ricerca di equilibrio                                                                                                 between the spatiality of the spaces,                                                           the historical and non-uniform nature
                                                                                                                                                                                     solutions must be studied on the
  tra la spazialità degli ambienti, il                                                                                               respect for the building’s historical and                                                       of the aggregate. Hence the need for
                                                                                                                                                                                     specificity of the environment and its
  rispetto della natura storico artistica                                                                                            artistic nature, the formal complexity of                                                       a denomination of the elements that
                                                                                                                                                                                     needs, the verification of heights and
  dell’edificio, la complessità formale                                                                                              the whole and the well-being of future                                                          would give decisive information about
                                                                                                                                                                                     minimum dimensions is carried out room
  dell’insieme e il benessere dei futuri                                                                                             users. Particular attention has been                                                            the type of element, its dimensions, its
                                                                                                                                                                                     by room, with particular attention to the
  fruitori. Attenzione particolare è posta                                                                                           paid to the study of acoustic insulation,                                                       material, even at the first reading, while
                                                                                                                                                                                     lofts.
  allo studio dell’isolamento acustico, che                                                                                          which in such a complex risks creating                                                          maintaining a streamlined coding that
  in un complesso così articolato rischia                                                                                            inconvenience at the time of use,                                                               would allow easy daily use, considering
  di creare disagi al momento della                                                                                                  and to the difficult coordination with          Checking minimum                                the great variety of types that would be
  fruizione, e al difficile coordinamento                                                                                            the structural and plant engineering            requirements                                    presented. The choice was made to use
  con le discipline strutturali e                                                                                                    disciplines, as we always work within the                                                       a coding system that would allow the
                                                                                                                                                                                     A fundamental step in architectural
  impiantistiche, in quanto si opera                                                                                                 rigid, albeit fascinating, limits imposed by                                                    immediate identification of the object, in
                                                                                                                                                                                     design is the verification of the regulatory
  sempre all’interno dei rigidi, seppur                                                                                              an existing listed building.                                                                    its type, material and size. The following
                                                                                                                                                                                     requirements of the rooms and the
  affascinanti, limiti che un edificio                                                                                                                                                                                               is an example of a frame code, W.1BR.(R)
                                                                                                                                                                                     correspondence of the project to the
  esistente vincolato pone.                                                                                                                                                                                                          (L).65x210, to indicate the type (window -
                                                                                                                                     From a thermal point of view, the               requirements of the Building Regulations.
  Dal punto di vista termico l’isolamento                                                                                                                                                                                            category W), which has a single casement
                                                                                                                                     insulation is placed inside the building,       Verification of RAI report and related
  viene posto all’interno dell’edificio, per                                                                                                                                                                                         with tilt and turn opening (code 1BR),
                                                                                                                                     so as not to affect the exterior elevations,    graphic display
  non andare ad intaccare i prospetti                                                                                                                                                                                                rectangular shape without fanlight (code
                                                                                                                                     which are bound and recently restored.
  esterni vincolati e recentemente                                                                                                                                                                                                   (R)), with wooden casement and frame
  restaurati. L’isolamento acustico                                                                                                                                                                                                  (code (L)), size 65x210 cm.
  interessa tutti i divisori orizzontali
                                                stanza per stanza, con particolare     lettura informazioni determinanti             ▼ Verifica rapporto RAI e relativa visualizzazione grafica. Tabelle di impostazione delle
  e verticali tra unità diverse prima e                                                                                              codifiche suddivise per categoria, in questo caso categoria W-Finestre.
                                                attenzione ai locali soppalcati.       circa la tipologia di elemento, le sue
  all’interno della stessa unità dopo,                                                                                               Verification of RAI report and related graphic display. Coding tables divided by category, in
                                                                                       dimensioni, il suo materiale, pur
  andando a colmare i possibili ponti                                                                                                this case category W-Windows.
                                                                                       mantenendo una snellezza di codifica
  acustici che i passaggi impiantistici         Verifica dei riquisiti minimi          che ne permettesse il facile utilizzo
  posso presentare. Attenzione                  Un passaggio fondamentale della        quotidiano, considerando la grande                                                                                                            Tutte queste informazioni sono
  particolare viene data ai soppalchi in        progettazione architettonica è la      varietà di tipologie che si sarebbero
                                                                                                                                                                                                                                     associate agli oggetti trami-
  acciaio e tavolato ligneo, attutendo le       verifica dei requisiti minimi degli                                                                                                                                                  te parametri nativi e/o creati
                                                                                       presentate. La scelta si è portata su una
  vibrazioni dei passi che si ripercuotono      ambienti e la corrispondenza                                                                                                                                                         appositamente, e sono quindi
                                                                                       codifica che portasse alla immediata
  sulla struttura, così come vengono            del progetto alle prescrizioni del
                                                                                                                                                                                                                                     sempre disponibili per opera-
                                                                                       identificazione dell’oggetto, nella sua                                                                                                       zioni di controllo, conteggio e
  attentamente isolate le colonne               Regolamento Edilizio.                  tipologia, materiale e dimensione.                                                                                                            modifica, nonché essenziali per
  impiantistiche che attraversano
                                                                                       Di seguito un esempio di codifica di                                                                                                          l’impostazione delle regole di
  l’edificio da cielo a terra. La complessità
                                                Codifica degli elementi                serramento, W.1BR.(R)(L).65x210, ad                                                                                                           computo.
  spaziale del luogo costituisce una
                                                L’impostazione delle codifiche         indicare la tipologia (finestra - categoria
  sfida per la progettazione: edifici vicini                                                                                                                                                                                         All this information is associa-
                                                degli elementi è stata una fase        W), che ha una singola anta con
  ma diversi tra loro devono dialogare                                                                                                                                                                                               ted with the objects by means
                                                importante e necessaria per la         apertura a battente ribalta (codifica
  in modo armonico, le soluzioni                                                                                                                                                                                                     of native and/or specially crea-
                                                natura storica e decisamente non       1BR), di forma rettangolare senza
  architettoniche devono essere studiate                                                                                                                                                                                             ted parameters, and is therefo-
                                                                                       sopraluce (codifica (R)), con anta e
  sulla specificità dell’ambiente e le          uniforme dell’aggregato. Da qui la                                                                                                                                                   re always available for control,
                                                                                       telaio lignei (codifica (L)), di dimensioni
  sue necessità, la verifica di altezze e       necessità di una denominazione degli                                                                                                                                                 counting and modification ope-
                                                elementi che desse già alla prima      65x210 cm.                                                                                                                                    rations, as well as essential for
  dimensioni minime viene effettuata
                                                                                                                                                                                                                                     setting calculation rules.
26 PALAZZO ROCCABONELLA                                                                                                                ROCCABONELLA PALACE 27

  7          La progettazione impianti
             System design

  Criteri di progettazione
                                                                                             ► Modellazione fase esecutiva centrale
  La sfida del progetto è quella di coniugare il rispetto del complesso edilizio, così       frigorifera
  come ci è stato donato dalla storia, e le moderne richieste di comfort abitativo. Ci       Modelling of the executive phase of the
  si è posti inoltre l’obiettivo di contenere il fabbisogno energetico e la produzione       refrigeration plant
  di inquinanti, riducendo i costi gestionali e l’impronta ambientale dell’edificio nel
  futuro, anche in considerazione della sua ubicazione.

  La modellazione tridimensionale della complessità spaziale dell’edificio e l’accesso
  alla visualizzazione della nuvola di punti comodamente dalle postazioni di
  lavoro ha aiutato molto la progettazione impiantistica nella scelta per percorsi di
  distribuzione e nel posizionamento degli elementi impiantistici. Tutti gli impianti
  sono stati modellati e catalogati secondo le WBS precedentemente illustrate
  (Edificio, Zona, Livello e Appartamento) permettendo in seguito una efficiente
  catalogazione e computazione.
  La natura irregolare e storica dell’intervento ha richiesto uno studio puntuale
  stanza per stanza riguardo alla collocazione di ogni elemento, cercando il più
  possibile di sfruttare nicchie esistenti o cambi di quota e collaborando a stretto
  contatto con la disciplina architettonica nel mascheramento degli impianti e nella
  scelta dei percorsi.

  Design criteria                                                                            ► Modellazione fase esecutiva centrale
                                                                                             idrica
  The challenge of the project is to combine respect for the building complex, as it
                                                                                             Modelling of the executive phase of the
  has been given to us by history, and modern demands for living comfort. The aim
                                                                                             water plant
  was also to reduce energy requirements and the production of pollutants, reducing
  management costs and the environmental footprint of the building in the future, also
  in view of its location.

  Three-dimensional modelling of the building’s spatial complexity and access to point
  cloud visualisation from the comfort of the workstations greatly aided the plant
  design in the selection of distribution paths and positioning of plant elements. All the
  installations were modelled and catalogued according to the WBSs illustrated above
  (Building, Zone, Level and Apartment) allowing efficient cataloguing and computation.
  The irregular and historical nature of the intervention required a precise room-by-
  room study of the location of each element, trying as much as possible to exploit
  existing niches or changes in height and working closely with the architectural
  discipline in the masking of the installations and the choice of routes.
28 PALAZZO ROCCABONELLA                                                                                                                                               ROCCABONELLA PALACE 29

  7
                                                                                              ◄ Modello meccanico alla fase esecutiva: in
                                                                                              rosso ventilconvettori canalizzati,
                                                                                               in azzurro distribuzione tubazioni e in blu
                                                                                              attrezzatura impianti
                                                                                              Mechanical model at the execution stage:
                                                                                              in red ducted fan coils, in blue piping
                                                                                              distribution and in blue plant equipment

  Impianti Meccanici                                                                          Mechanical system
  Il complesso viene dotato di impianti di climatizzazione invernale ed estiva in             The complex is equipped with winter and summer air conditioning systems capable
  grado di fornire un livello di comfort elevato, secondo i più moderni standard qua-         of providing a high level of comfort, according to the most modern quality standards.
  litativi. La generazione termofrigorifera e sanitaria è centralizzata condominiale          The thermo-cooling and sanitary generation is centralised in the condominium with
  con un innovativo impianto geotermico, in grado di prelevare calore dal terreno             an innovative geothermal system, able to take heat from the ground below in the
  sottostante nella stagione invernale per poi restituirlo in estate. Il sistema predi-       winter season and return it in the summer. The system is based on closed-circuit ge-
  sposto conta su geosonde a circuito chiuso (che non prevedono pertanto alcun                othermal probes (which do not draw water from the underground aquifers), capable
  spillamento di acqua dalle falde sotterranee), in grado di scambiare calore con il          of exchanging heat with the surrounding ground. This heat collection and return
  terreno circostante. Tale rete di captazione e restituzione termica è stata posata          network was laid in the foundations underneath the underground car park, relying on
  nelle fondazioni al di sotto del parcheggio interrato, potendo contare su una ele-          the high thermal stability of the deep soil. The geothermal plant is able to meet about
  vata stabilità termica del terreno in profondità. L’impianto geotermico è in grado          half of the annual energy demand. During periods of maximum thermal demand, it
  di sopperire a circa metà della richiesta energetica annua. Nei periodi di massima          will be assisted by methane gas-fired condensing heat generators, capable of
  richiesta termica sarà coadiuvato da generatori di calore a condensazione ali-              ensuring maximum reliability. At the same time the maximum cooling capacity will be
  mentati a gas metano, in grado di assicurare la massima affidabilità. Allo stesso           supplemented by a traditional air-cooled refrigeration system.
  tempo la massima potenza frigorifera sarà integrata da un sistema frigorifero               The rooms will preferably be heated with modern radiant heating systems integrated,
  tradizionale con condensazione ad aria.                                                     as far as possible, into the floors.
  I locali saranno preferibilmente riscaldati con moderni sistemi di riscaldamento            Cooling will be provided by convective systems also built into niches or hidden in
  radianti integrati, per quanto possibile, nelle pavimentazioni.                             the finishes.
  Il raffrescamento è invece affidato a sistemi convettivi incassati anch’essi in
  nicchie o nascosti nelle finiture.
                                                                                              Electrical system
                                                                                              The electrical system includes LED lighting systems capable of ensuring full use of
  Impianti elettrici                                                                          the internal and external condominium spaces and at the same time enhancing the
  La dotazione elettrica prevede sistemi di illuminazione a led in grado di assicura-         architecture even at night.
  re la piena fruizione degli spazi condominiali interni ed esterni ed al contempo la         The residential units are set up for domotic management, a modular and flexible
  valorizzazione dell’architettura anche in regime notturno.                                  system that responds to all the main plant engineering needs of the house. This sy-
  Le unità abitative sono predisposte per la gestione domotica, un sistema mo-                stem allows the use of modern, cutting-edge technical solutions for the management
  dulare e flessibile che risponde a tutte le principali esigenze impiantistiche della        of ambient lighting and dimming systems, control of loads, temperature control, video
  casa. Tale sistema permette l’utilizzo di soluzioni tecniche moderne e all’avan-            telephony and connection to smart appliances (IoT), allowing them to be managed
  guardia per la gestione dei sistemi di illuminazione ambientale e di oscuramento,           using an intelligent voice assistant, but above all remotely via smartphone.
  il controllo dei caritchi, la termoregolazione, la videofonia e la connessione agli         A sophisticated CCTV closed-circuit video recording system and anti-theft
  elettrodomestici smart (IoT), consentendone la gestione anche tramite assistente            equipment ensure the security of private and condominium spaces, both indoor and
  intelligente vocale, ma soprattutto via smartphone da remoto.                               outdoor.
  Un sofisticato sistema di registrazione video a circuito chiuso TVCC e le dota-             The electrical system is also entrusted with the task of powering the systems and lifts
  zioni antifurto assicurano la sicurezza degli spazi privati e condominiali, sia interni     that ensure easy movement up and down the floors. Particular care is also taken to
  che esterni.                                                                                contain noise emissions, both from internal and external plant equipment, and from
  All’impianto elettrico viene affidato anche il compito di alimentare gli impianti e         distribution and exhaust networks, restoring high levels of comfort to tenants.
  gli ascensori che assicurano un agevole spostamento ai piani. Particolare cura
  viene posta anche al contenimento delle emissioni acustiche, sia delle dotazioni
                                                                                              ◄ Modello elettrico alla fase esecutiva: in arancione le canaline elettriche di distribuzione
  impiantistiche interne ed esterne, sia delle reti distributive che delle reti di scarico,   piani interrati, in azzurro i tubi corrugati dei montanti principali, in giallo i corpi
  restituendo elevati livelli di confort agli inquilini.                                      illuminanti e in nero i dispositivi elettrici
                                                                                              Electrical model at the execution stage: in orange the underground electrical distribution
                                                                                              ducts, in blue the corrugated pipes of the main uprights, in yellow the lighting fixtures and
                                                                                              in black the electrical equipment
30 PALAZZO ROCCABONELLA                                                                                                                                                                                                                                     ROCCABONELLA PALACE 31

  8          Il bim 5D la computazione integrata
             Bim 5D integrated computing

  ► Sezione rappresentanti le varie fasi della
  progettazione, dal rilievo laser scanner alla
  progettazione esecutiva
  Section representing the various stages
  of design, from laser scanner survey to
  executive design

  Una volta che i modelli BIM, suddivisi per disciplina, raggiun-     fibrorinforzato); nel caso invece questa quantità non fosse in      Once the BIM models, subdivided by discipline, reach a suitable       ty cannot be derived in any way (e.g. temporary works absent in
  gono un livello di coordinamento e verifica adeguati possono        nessun modo derivabile (es. opere provvisionali assenti nei         level of coordination and verification they can be exported in        the IFC models), the software allows explicit (manual) insertion
  essere esportati in formato IFC 2x3 ai fini della computa-          modelli IFC) il software ci consente comunque un inserimen-         IFC 2x3 format for quantitative and economic computa-                 of the values. An entry that is not derived from a calculation
  zione quantitativa ed economica.                                    to esplicito (manuale) dei valori. Un inserimento che non           tion purposes.                                                        rule will remain traceable and groupable separately from the
  I file IFC2x3 così esportati vengono quindi importati nel           deriva da regola di calcolo rimarrà tracciabile e raggruppabi-      The exported IFC2x3 files are then imported into the manage-          other types of QTO.
  software di gestione e QTO Team System CPM (ex STR Vision           le distintamente dagli altri tipi di QTO.                           ment and QTO software Team System CPM (formerly STR Vision            Each article in the price list will now be identified within the
  CPM, da qui in poi sinteticamente TS CPM).                          Ogni articolo dell’elenco prezzi a questo punto sarà quindi         CPM, from now on briefly TS CPM).                                     multilevel WBS listed above, by Building, Zone and Work.
  Da qui si procede a filtrare gli attributi tramite regole e col-    identificato all’interno delle WBS multilivello elencate prece-     From here the attributes are filtered using rules and linked          Once this preliminary work is done, a complete, co-ordinated
  legarli di conseguenza alle distinte voci di elenco prezzi. La      dentemente, per Edificio, Zona e Lavorazione.                       accordingly to the separate price list entries. The mapping will      and updatable structure of:
  mappatura avverrà per ogni rilevazione secondo due regole:          Fatto questo lavoro preliminare si ottiene nella singola            take place for each survey according to two rules:                    • IFC models subdivided by discipline, with single com-
                                                                      piattaforma TS CPM una struttura completa, coordinata ed                                                                                  ponents (IFC elements) mapped to the reference machining
  • una regola di filtro, che discernerà quali elementi pescare       aggiornabile di:                                                    • a filtering rule, which will discern which elements to pick up      operations
  • una regola di calcolo, che dagli elementi precedentemente         • modelli IFC suddivisi per disciplina, con singoli compo-          • a calculation rule, which, from the previously filtered elemen-     • price list, generated from time to time by the survey rules
  filtrati sceglierà quali parametri utilizzare al fine del calcolo   nenti (IFC elements) mappati alle lavorazioni di riferimento        ts, will choose which parameters to use for the calculation of        prepared on the IFC models and linked and co-ordinated to
  delle quantità                                                      • elenco prezzi, generato di volta in volta dalle regole di rile-   quantities.                                                           reference price lists and possibly to new price analysis sheets
  Tale operazione viene fatta estensivamente al primo carica-         vazione predisposte sui modelli IFC e collegato e coordinato        This operation is carried out extensively on the first loading,       • set of surveys (calculation) grouped by WBS and possible
  mento, successivamente solo per nuove voci e attributi. Nel         a listini di riferimento ed eventualmente alle schede di analisi    and then only for new items and attributes. If the desired quan-      free groupers, mapped to the factory elements they refer to
  caso la quantità ricercata non sia riscontrabile direttamen-        nuovi prezzi                                                        tity cannot be found directly in the model, there are two ways        implicitly, if the outcome of the machining is represented in one
  te nel modello si aprono due strade: nel caso la quantità           • assieme di rilevazioni (computo) raggruppato per WBS              to proceed: if the desired quantity can be derived from a value       of the IFC models, and explicitly in case the machining is not
  desiderata sia derivabile da un valore leggibile nell’oggetto       ed eventuali raggruppatori liberi, mappate agli elementi di         that can be read in the object, it can be obtained by inserting a     represented in the three-dimensional models
  questa può essere ottenuta inserendo nella regola di calcolo        fabbrica cui riferiscono implicitamente, qualora l’esito della      static value in the calculation rule (e.g. incidence of kg/mc fibre   geometric representation in the three-dimensional models
  un valore statico (es. incidenza di kg/mc fibra per cemento         lavorazione risulti rappresentata in uno dei modelli IFC.           for fibre-reinforced concrete); if, on the other hand, this quanti-
Puoi anche leggere