Cell Culture Laboratories Organisation 03.03.2020
←
→
Trascrizione del contenuto della pagina
Se il tuo browser non visualizza correttamente la pagina, ti preghiamo di leggere il contenuto della pagina quaggiù
1. Sterile handing 2. Preparation 3. Wash up 4. Incubation Cell culture laboratory 5. Sterilisation 6. Storage Al momento di aprire un nuovo laboratorio di colture cellulari, sarebbe opportuno: - allestire stanze facili da pulire - avere un sistema di filtrazione dell’aria - avere stanze (posto) separate per le colture cellulari, la preparazione di medium/soluzioni e materiale biologico, - la lavanderia e l’area per la sterilizzazione - non avere i laboratori di microbiologia, stabulari e stalle vicini al laboratorio di colture cellulari
Cold Hot Sterile glassware room Liquids, Plastic room Aseptic Area Microscope room Nitrogen Room Quarantine room corridor storage Prep Ovens and Wash up Area autoclave Area Area Sterile Area del laboratorio dove si effettuano unicamente le colture cellulari; non deve esserci traffico e altri fattori che possano favorire le contaminazioni. In questa area è consigliabile avere piani di lavoro di colore chiaro per favorire l’osservazione delle colture (ed eventuali contaminazioni o cambi di pH), avere una cappa a flusso laminare e uno spazio provvisto di cell counter e microscopio invertito.
I * Area di Quarantena/Contenimento: * area aseptica separata dal laboratorio per le colture cellulari dove si lavora con linee cellulari e biopsie appena arrivate nel laboratorio. Prima di introdurle nell’area aseptica è necessario verificare che il nuovo materiale biologico sia privo di alcuna contaminazione. I Area per incubatori le incubazioni dovrebbero essere portate avanti in incubatori distinti o in una stanza a temperatura controllata. Se vengono utilizzati più di due incubatori è conveniente avere una stanza calda provvista di un apposito riscaldamento, un sistema di circolazione dell’aria, un termostato, un temperature recorder.
Aseptic Techniques - Controlled environment (Traffic, air flow) - Sterile media and reagents - Avoid aerial contamination of solutions - Avoid manual contamination of equipment - Avoid repeated opening of bottles - Swab all bottle tops & necks with 70% ethanol - UV irradiation before and after - Only use disposable equipment once - Flame all bottle necks & pipette by passing very quickly through the hottest part of the flame - Avoiding placing caps & pipettes down on the bench; practice holding bottle tops with the little finger - Work either left to right or vice versa, so that all material goes to one side, once finished - Clean up spills immediately & always leave the work place neat & tidy
Aseptic Techniques - Lab coat (only in lab) - Gloves - Tip DOES not touch anything than medium/reagent - Holding off the tube
Attrezzature di laboratorio https://www.youtube.com/watch?v=CA5fVLK5zAE Please watch it Laminar Incubatore Centrifuga Microscopio pH metro Osmometro
Attrezzature di laboratorio - Laminar cabinet (Vertical are preferable) - Incubation facilities - Temperature of 25-30°C for insect & 37°C for mammalian cells, - CO2 2-5% & 95% air at 99% relative humidity. - To prevent cell death incubators set to cut out at approx. 38.5 C - Refrigerators: Liquid media kept at 4°C, enzymes (e.g. trypsin) & media components (e.g. glutamine & serum) at -20 C - Microscope: An inverted microscope with 10x to 100x magnification
Laminar-Flow Hood - Cappa a floss laminare Most tissue culture work is done in a laminar flow hood. The major advantage of this is that the working environment is protected from dust and contamination by a constant, stable flow of filtered air passing over the work surface. There are two types: - Horizontal: gives the most stable airflow and best sterile protection to the culture and reagents - Vertical: gives more protection to the operators
Classes of Cell Culture Hoods Class I Class I cell culture hoods offer significant levels of protection to laboratory personnel and to the environment when used with good microbiological techniques, but they do not provide cultures protection from contamination. They are similar in design and air flow characteristics to chemical fume hoods. Class II Class II cell culture hoods are designed for work involving dangerous materials, and they also provide an aseptic environment necessary for cell culture experiments. A Class II biosafety cabinet should be used for handling potentially hazardous materials (e.g., primate-derived cultures, virally infected cultures, radioisotopes, carcinogenic or toxic reagents). Class III Class III biosafety cabinets are gas-tight, and they provide the highest attainable level of protection to personnel and the environment. A Class III biosafety cabinet is required for work involving known human pathogens and other very hazardous materials.
CO2 Incubator Some vessels, e.g., Petri dishes or multi-well plates, require a controlled atmosphere with high humidity and elevated CO2 tension. Incubator provide the appropriate enviroment for cell growth. Should: - be large enough - have controlled temperature - CO2 and eventual O2 gas - be easy cleanable - Not corrosion - be clean et least once/ two months There are two types: - dry incubator (cheaper): cells needs to be cultured in closed flasks to avoid evaporation - humid incubators (more expensive): allow superior control of culture conditions
Centrifuga Le sospensioni cellulari necessitano di essere centrifugate per: - Rimuovere reagenti - Splittare le cellule - “Pull down” liquids - for cells growing in suspension
Inverted Microscope A morphological change is often the first sign of deterioration in a culture and the characteristic pattern of microbiological infection is easily recognized. Often is connected with good quality optic photo/movie system. Fluorescent optic to observe fluorescence in cells. Permette di osservare le cellule in coltura: - Morfologia delle cellule - Verificare eventuale contamination - Confluenza - Eventuali contaminazioni
OTHERs Bilancia Water Purification System - Purified water is required for rinsing glassware, dissolving powdered media, and diluting concentrates. Bilancia La bilancia di precisione è necessaria per pesare le diverse componenti di medium/soluzioni. Il pH metro permette di verificare e/o correggere il pH di medium/ soluzioni L’osmometro permette di verificare “l’osmolarità”, una importante proprietà fisica dei medium per colture cellulari
OTHERs Sostituisce la pasteur + tettarella. Permette una maggiore accuratezze e riproducibilità. Le pipette sono generalmente provviste di filtri per ridurre la possibilità di contaminazioni Strumenti non sterili ma utilizzati con puntali sterili con/senza filtro. Permettono di utilizzare volumi piccoli < 1 ml. Cell counter (automatico) o camera di Burcher
OTHERs - storage Frigorifero (+4°C) Freezer (-20 e -80°C) Bidone Azoto
Attrezzature per lavare e sterilizzare materiali/ soluzioni Lavandino Stufa Lavandino Stuffa Autoclave Autoclave Lavastoviglie Lavastovigie