Razionale Acido ialuronico e h 2O2: Italian Journal of Public Health

Pagina creata da Gaia Mattei
 
CONTINUA A LEGGERE
Razionale Acido ialuronico e h 2O2: Italian Journal of Public Health
QIJPH - 2019, Volume 8, Number 4

Acido ialuronico e h2O2:
       Razionale
 ed esperienze cliniche
    in dermatologia

    SI RINGRAZIANO TUTTI GLI ESPERTI CHE HANNO FORNITO I CONTRIBUTI SCIENTIFICI
                                     Anna Cammisa
       Consulente e Libero Professionista come Dermatologo, Ospedale San Raffaele

                                      Silvio Masci
                  Clinica Dermatologica, Università degli Studi di Chieti

  Elisa Cinotti, Giovanni Ghigliotti, Giuseppe Gianotti, Paolo Tavilla, Aurora Parodi
                 Clinica Dermatologica, Università degli Studi di Genova
Razionale Acido ialuronico e h 2O2: Italian Journal of Public Health
QIJPH - 2019, Volume 8, Number 4

     ITALIAN JOURNAL OF PUBLIC HEALTH

II                                 CAPITOLO 1
QIJPH - 2019, Volume 8, Number 4

                    ITALIAN JOURNAL OF PUBLIC HEALTH

Indice

1   CAPITOLO 1
    PEROSSIDO DI IDROGENO ED ACIDO IALURONICO
    Anna Cammisa . ............................................................................................................................             1

2   CAPITOLO 2
    SICUREZZA ED EFFICACIA DI UN PREPARATO DI ACQUA OSSIGENATA E ACIDO IALURONICO
    Silvio Masci ..................................................................................................................................         4

3   CAPITOLO 3
    USO POSTCHIRURGICO DI UN GEL A BASE D'ACIDO IALURONICO E PEROSSIDO D'IDROGENO
    NELL'OTTIMIZZAZIONE DEL PROCESSO DI CICATRIZZAZIONE
    Elisa Cinotti, Giovanni Ghigliotti, Giuseppe Gianotti, Paolo Tavilla, Aurora Parodi .......................                                             6

4   CAPITOLO 4
    STUDIO CLINICO DI UN NUOVO PREPARATO A BASE DI H2O2 E ACIDO IALURONICO
    Anna Cammisa, Silvio Masci .........................................................................................................                11

5   CAPITOLO 5
    STUDIO CLINICO SULL'EFFICACIA DI UN NUOVO PREPARATO A BASE DI H2O2 E
    ACIDO IALURONICO NEL TRATTAMENTO DELLE PICCOLE USTIONI
    Anna Cammisa, Silvio Masci .........................................................................................................                12

                                                       C A P IITNODLIOC E1                                                                            III
QIJPH - 2019, Volume 8, Number 4

ITALIAN JOURNAL OF PUBLIC HEALTH

                             INDICE
QIJPH - 2019, Volume 8, Number 4

                 ITALIAN JOURNAL OF PUBLIC HEALTH

Perossido di idrogeno ed acido
ialuronico
Anna Cammisa

IL PEROSSIDO DI IDROGENO                             di alcuni lieviti, quali Candida albicans ed
                                                     Aspergillus niger ed alcuni virus quali Herpes
     Il perossido di idrogeno, noto anche come       simplex tipo 1 e 2. Nelle sperimentazioni finora
acqua ossigenata, è il più semplice dei perossidi    eseguite, non ha mai mostrato sviluppo di
ed è un forte ossidante.                             antibiotico-resistenza.
     Il perossido di idrogeno presenta la formula          Molti studi dimostrano che, nei processi di
chimica H2O2 e la seguente formula strutturale:      riparazione tessutale, il perossido di idrogeno
H-O-O-H.                                             oltre ad agire come antisettico, stimola il rilascio
     Il perossido e' un composto contenente ioni     di prostaciclina, fattore di crescita endoteliale
perossido (O22-). Gli ioni perossido consistono      vascolare (si ha infatti un notevole aumento
in legame singolo: (O-O)2-. La molecola del          della neovascolarizzazione), e ossigeno: l’azione
perossido di idrogeno contiene un atomo di           combinata di questi fattori accelera il processo
ossigeno supplementare, rispetto alla molecola       di guarigione [1].
d’acqua più stabile.                                       Ad alte concentrazioni può essere citotossico
     Il legame fra i due atomi di ossigeno,          sui fibroblasti in cultura, a basse concentrazioni
il cosiddetto legame perossido, si rompe             stimola la proliferazione dei fibroblasti e
formando due radicali H-O. Tali radicali             l’attivazione di metalloproteinasi [2].
reagiscono rapidamente con altre sostanze,                 Le metalloproteinasi oltre a degradare il
mentre si formano nuovi radicali ed avvine una       collagene nel tessuto necrotico stimolano la
reazione a catena.                                   neoangiogenesi con conseguente aumento del
     Le soluzioni di perossido di idrogeno sono      flusso sanguigno.
simili all'acqua e possono essere dissolte in              Le più recenti formulazioni costituite
acqua. Ad alte concentrazioni tali soluzioni         da speciali veicolazioni lipidiche a base di
emanano un'irritante odore acido. Il perossido       monogliceridi cristallizzati rendono più stabile
di idrogeno è infiammabile. A basse temperature      la molecola e permetteno un rilascio graduale
diventa solido. La quantità di perossido di          del principio attivo, anche per molte ore,
idrogeno in soluzione è espressa in peso             con prolungamento notevole della durata
percentuale. Per il trattamento delle lesioni        d’azione del perossido di idrogeno. Tali veicoli
cutanee vengono         usate concentrazioni di      inducono la formazione di una sottile pellicola
perossido di idrogeno al 3 o 6%.                     stabile, protettiva nei confronti di eventuali
     Il perossido di idrogeno è un antisettico       contaminazioni ambientali nonché traspirante
ben conosciuto ed efficace nei confronti di          all’acqua ed ai gas. In tal modo la non
molti microrganismi patogeni. Per il suo ampio       occlusività del topico consente l’utilizzo e
spettro d’azione è indicato in svariate patologie    l’attività del perossido di idrogeno anche su
dermatologiche: acne, follicoliti, ulcere di varia   superfici umide, in presenza di siero [3].
natura e nelle piodermiti primarie o secondarie,           Le caratteristiche riportate, l’assenza di
specie in presenza di ceppi batterici antibiotico-   effetti collaterali, ad eccezione di una breve,
resistenti.                                          fugace e saltuaria sensazione di bruciore nel
     La sua attività antimicrobica si esplica        sito di applicazione, la gradevolezza cosmetica,
principalmente contro i batteri GRAM+ e GRAM-        l’assenza di fenomeni di resistenza ed il basso
inclusi Stafilococchi, Haemophilus influenzae,       costo, rendono facilmente praticabile questa
Escherichia coli, Pseudomonas aeruginosa,            terapia topica in ambito dermatologico.
Proteus mirabilis, ma anche nei confronti                  La liberazione dei radicali liberi dell’ossigeno

                                           CAPITOLO 1                                                  1
QIJPH - 2019, Volume 8, Number 4

                  ITALIAN JOURNAL OF PUBLIC HEALTH

dall’H2O2 e’ operata dalle catalisi tissutali           solo in presenza di acqua) e la temperatura (è
(enzimi che distruggono i composti di origine           favorito dalle basse temperature).
endogena); il meccanismo è simile a quello che               I batteri dimostrano una diversa sensibilità
l’organismo utilizza con la formazione di una           ai radicali: i Gram-negativi sono meno sensibili
sostanza ossidante da parte dei leucociti adibiti       dei Gram-positivi ed i batteri sporigeni sono
alla fagocitosi batterica (Figura 1).                   più resistenti dei non sporigeni.
                                                                L’azione dei radicali sui virus consiste non
      FIGURA 1                                          in una distruzione, come nel caso dei batteri,
                                                        ma in una inattivazione dei recettori cellulari
                                                        presenti sulla superficie virale, impedendo così
                                                        il contatto tra virus e cellula bersaglio (se il
                                                        virus non penetra nella cellula non è in grado
                                                        di replicarsi). Si determina in tal modo un
                                                        arresto del meccanismo di riproduzione virale
                                                        a livello della prima fase di invasione cellulare.

                                                        L'ACIDO IALURONICO

                                                             L'acido Ialuronico è uno dei componenti
                                                        fondamentali del tessuto connettivo dell'uomo,
                                                        conferisce alla cute quelle sue particolari
                                                        proprietà di resistenza e mantenimento
                                                        della forma. Una sua mancanza determina
                                                        un indebolimento della cute promuovendo
                                                        la formazione di rughe ed inestetismi. La sua
                                                        concentrazione nei tessuti del corpo tende a
                                                        dimuire con l'età.
                                                             Chimicamente è definibile come un
                                                        glicosaminoglicano dalla catena polisaccaridica
     Il meccanismo di disinfezione è basato             non ramificata prodotta dall'aggregazione di
sul rilascio di radicali liberi di ossigeno:            migliaia di unità disaccaridiche formate a
H2O2 → H2O + O2                                         loro volta da residui di acido glicuronico (un
     I radicali liberi sono molecole (gruppi            derivato del glucosio) e N-acetilglucosamina
d’atomi legati tra loro) instabili. In pratica,         (Figura 2).
molecole a cui "manca qualcosa" (possiedono
un solo elettrone anziché due), pronte a reagire            FIGURA 2
con qualsiasi altra molecola con cui vengono a
contatto, per appropriarsi di un loro elettrone;
così queste molecole diventano instabili a loro
volta e ricercano un elettrone, innescando
in questo modo un meccanismo d’instabilità
a “catena”. Possiamo immaginarli come una
“pistola” carica pronta a far fuoco su qualsiasi
innocente molecola che entri in contatto con
loro. Questa serie di reazioni può durare da
frazioni di secondo ad alcune ore e può essere
ridimensionata o arrestata solo dalla presenza
degli antiossidanti.
     L’azione distruttrice è resa possibile
dall’affinità dei radicali liberi per i componenti
lipoproteici della capsula e dall’insufficiente              In vivo tutti i gruppi carbossilici ed
capacità di difesa della cellula batterica. L’effetto   idrossilici dell'acido glicuronico e della
germicida è sotto l’influenza di alcuni fattori,        N-acetilglucosamina sono completamente
tra cui il grado di umidità (l’azione si esplica        ionizzati conferendo alla molecola di acido

  2                                               CAPITOLO 1
QIJPH - 2019, Volume 8, Number 4

                      ITALIAN JOURNAL OF PUBLIC HEALTH

ialuronico elevata polarità, cioè elevata solubilità              la diffusione libera nel tessuto di particolari
in acqua (alcuni calcoli affermano che 1g di                      sostanze, batteri, agenti infettanti. Solamente
acido ialuronico sia in grado di complessare                      le sostanze dal peso molecolare abbastanza
addirittura 3 litri d'acqua).                                     basso da poter passare attraverso le "maglie" di
     Grazie a questa sua proprietà l'acido                        questa rete potranno diffondere liberamente nel
ialuronico è in grado di complessarsi con                         tessuto; tutte le sostanze dal peso molecolare
moltissime molecole di acqua (cosa che                            maggiore come anche batteri o virus rimarranno
gli procura un elevato ingombro sterico)                          impigliate nella rete.
raggiungendo un elevato grado di idratazione.                          Oltre a svolgere un’azione ristrutturante
Nella matrice amorfa di un tessuto connettivo l'                  ed intensamente idratante della sostanza
acido ialuronico si occupa quindi di mantenerne                   intercellulare dermica (è come applicare e fare
il grado di idratazione, turgidità, plasticità                    agire una crema ricca di principi attivi idratanti
e viscosità. È anche in grado di agire come                       direttamente nel derma) interagisce con i
sostanza cementante e come molecola anti-urto                     fibroblasti stimolando la produzione di elastina
nonchè come efficiente lubrificante prevenendo                    e ulteriore acido ialuronico endogeno.
il danneggiamento delle cellule del tessuto da                             L’acido ialuronico è in grado di stimolare
stress fisici.                                                    la formazione di tessuto di granulazione e di
     L'estrema lunghezza della molecola insieme                   ridurre quella di tessuto fibroso accelerando
al suo alto grado di idratazione permette a più                   i tempi di guarigione. Inoltre, studi in vivo su
polimeri di acido ialuronico di organizzarsi a                    animali hanno dimostrato che l’applicazione
formare una struttura di tipo reticolare che ha                   ripetitiva di acido ialuronico stimola i fibroblasti
due principali funzioni:creare un'impalcatura                     a rilasciare una minore quantità di collagene,
molecolare per mantenere la forma ed il tono                      che si organizza in bande più sottili inducendo
del tessuto; funzionare come filtro contro                        la formazione di una cicatrice meno fibrosa.

Bibliografia
[1]   G.Belcaro, Phd, M.R. Cesarone, A.N. Nicolaides,                   pig: blood recruitment in multiple skin sites. Journal
      G. Geroulakos, A. Di Renzo, M.Milani, A.Ricci, G.                 of the American Academy of Dermatology August 217-
      Brandolini, M.Duggall, I.Ruffini, U. Cornelli, M.Griffin.         221, 1995
      Improvement of microcirculation and healing of              [3]   G.Belcaro, Phd, M.R. Cesarone, A.N. Nicolaides,
      venous hypertension and ulcers with Crystacide.                   G. Geroulakos, A. Di Renzo, M.Milani, A.Ricci, G.
      Evaluation of free radicals, laser Doppler flux and PO2.          Brandolini, M.Duggall, I.Ruffini, U. Cornelli, M.Griffin.
      A prospective-randomized-controlled study. Angiology              Improvement of microcirculation and healing of venous
      vol.54, N.3, 2003                                                 hypertension and ulcers with Crystacide. Evaluation
[2]   E. Tur, L. Bolton, B. E. Constantine. Topical hydrogen            of free radicals, laser Doppler flux and PO2. A
      peroxide treatment of ischemic ulcers in the guinea               prospective-randomized-controlled study. Angiology
                                                                        vol.54, N.3, 2003

                                                  CAPITOLO 1                                                                3
QIJPH - 2019, Volume 8, Number 4

                  ITALIAN JOURNAL OF PUBLIC HEALTH

Sicurezza ed efficacia di un preparato di
acqua ossigenata e acido ialuronico
Silvio Masci

SCOPO DELLO STUDIO
                                                       CRITERI DI INCLUSIONE ED ESCLUSIONE
     Lo scopo dello studio è quello di
valutare l'efficacia e la sicurezza del prodotto            Sono stati scelti soggetti diversi tra loro per
denominato, sia per quanto riguarda                    età, per categoria sociale, condizione coniugale
l'aspetto, sia per quanto riguarda la sua              (celibi, coniugati, conviventi, fidanzati). Sono
applicazione pratica.                                  stati esclusi soggetti al di sotto dei 10 anni e al
     Sono stati considerati anche gli aspetti          di sopra dei 70.
legati alla facilità d'uso, ai possibili effetti
collaterali quali dermatiti allergiche o irritative,
nonché eventuali effetti indesiderati legati           METODO
all'uso contemporaneo di farmaci per uso
topico.                                                     Ai pazienti sono stati consegnati sei tubi
                                                       insieme con un modulo di valutazione dove
                                                       riportare i seguenti parametri:
INTRODUZIONE                                                1. facilità d'uso della confezione;
                                                            2. eventuali disfunzioni del dispositivo:
     Il prodotto è stato valutato con due scopi                 rotture o degradazione del prodotto;
principali: la prevenzione delle infezioni e la             3. eventuali reazioni avverse indesiderate:
cicatrizzazione.                                                irritazioni, bruciore, sensibilizzazione
     Una vasta letteratura medica fornisce prove                ecc ....;
dell'elevata efficacia per entrambe le finalità, e          4. numero di applicazioni nel prodotto;
la valutazione clinica ha confermato sul campo              5. eventuale utilizzo contemporaneo di
queste attività.                                                farmaci;
                                                            6. efficacia.

TEMPI E MATERIALI
                                                       RISULTATI
     Lo studio ha avuto inizio il 10/01/2004 e si
è concluso il 31.10.2004                                   Sono stati inclusi nello studio n. 40 ( quaranta)
     I materiali di prova sono stati fomiti da         pazienti per un periodo di dodici settimane.
Drex Phanna Sri - preparati da Biokosmes Sri -             Non si sono osservati effetti avversi ritardati
per tutta la durata dello studio, in particolare è     legati all'uso del prodotto.
stato utilizzato il lotto pilota 34735.

                                                       CONCLUSIONE
SELEZIONE DEI PAZIENTI
                                                            In base ai risultati il prodotto risulta ben
    I pazienti sono stati selezionati nei Comuni       tollerato e di facile uso. Non si sono verificati
di Pescara e provincia; le modalità dello studio       casi di reazioni allergiche, di tossicità né di
sono state spiegate a tutti i pazienti che hanno       sensibilizzazione allergica al prodotto.
consentito liberamente a partecipare.                       Si    è    osservata     una    fisiologica
                                                       accelerazione del processo di cicatrizzazione

  4                                              CAPITOLO 2
QIJPH - 2019, Volume 8, Number 4

                 ITALIAN JOURNAL OF PUBLIC HEALTH

senza effetti collaterali.                                I dati relativi alla sperimentazione sono
     Il prodotto si è dimostrato ottimo ed           stati archiviati preso lo studio del Dr Silvio
efficace nell'indurre il miglioramento - fino alla   Masci.
guarigione - delle perionissi, delle follicoliti,         In conformità a quanto previsto dalla legge
delle escoriazioni, delle ferite, delle ustioni di   675/1996 di tutela della privacy.
grado lieve e delle ulcere post-traumatiche.

                                        CAPITOLO 2                                               5
QIJPH - 2019, Volume 8, Number 4

                   ITALIAN JOURNAL OF PUBLIC HEALTH

Uso postchirurgico di un gel a base
d'acido ialuronico e perossido
d'idrogeno nell'ottimizzazione del
processo di cicatrizzazione
Elisa Cinotti, Giovanni Ghigliotti, Giuseppe Gianotti, Paolo Tavilla, Aurora Parodi

     L'acido ialuronico è un componente                  Sono stati valutati l'infiammazione residua,
normale del tessuto connettivo che serve per             l'eventuale sovrainfezione batterica, il risultato
mantenere idratata e plastica la cute ed è               estetico e la tendenza alla formazione di cicatrice
conosciuto per le sue proprietà cicatrizzanti.           ipertrofica. Inotre sono stati considerati la
Recentemente è stata introdotta in commercio             tollerabilità del prodotto da parte del paziente
l'associazione tra acido ialuronico e perossido          e la sua accettabilità cosmetica.
d'idrogeno con formulazione in gel (Dermacit                   I risultati hanno dimostrato in tutti i casi
gel, Drex Pharma Sri, Milano) che garantisce             la formazione di un'accettabile cicatrice, priva
efficacia antisettica e potenzia la capacità             di segni d'infiammazione o di pigmentazione.
cicatrizzante.                                           Nessun paziente ha riferito effetti collaterali
     Al fine di valutare l'efficacia dell'associazione   degni di nota, se si eccettua una modesta
nell'ottimizzare il processo di guarigione dopo          irritazione cutanea insorta in alcuni casi
un intervento dermo-chirurgico sono stati                all'inizio della cura e poi risoltasi con la sua
reclutati 20 pazienti che erano stati sottoposti         prosecuzione.
ad asportazione di una neoformazione cutanea.                  In conclusione l'associazione in gel tra acido
I pazienti, dopo la rimozione dei punti di sutura,       ialuronico e perossido di idrogeno è efficace nel
hanno applicato a domicilio l'associazione 2             coadiuvare il processo di cicatrizzazione dopo
volte al giorno per 30 giorni.                           un intervento di dermochirurgia. La accettabilità
     Le ferite sono state fotografate al momento         cosmetica del prodotto è risultata elevata
della spuntatura, al 1° controllo effettuato a           trattandosi di un gel incolore, particolarmente
30 giorni al 2° controllo effettuato a 60 giorni.        indicato in caso di applicazione in sedi visibili.

  6                                                CAPITOLO 3
QIJPH - 2019, Volume 8, Number 4

             ITALIAN JOURNAL OF PUBLIC HEALTH

     Nevo giunzionale acrale                                     Rimozione dei punti

         Dopo 30 giorni                                            Dopo 60 giorni

Nevo claveare + bruciatura angioma                               Rimozione dei punti

         Dopo 30 giorni                                            Dopo 60 giorni

                                     CAPITOLO 3                                        7
QIJPH - 2019, Volume 8, Number 4

              ITALIAN JOURNAL OF PUBLIC HEALTH

    Nevo giunzionale displastico                          Rimozione dei punti

          Dopo 30 giorni                                    Dopo 60 giorni

        Carcinoma Sebaceo                                 Rimozione dei punti

          Dopo 30 giorni                                    Dopo 60 giorni

8                                            CAPITOLO 3
QIJPH - 2019, Volume 8, Number 4

   ITALIAN JOURNAL OF PUBLIC HEALTH

  Basalioma                                  Rimozione dei punti

Dopo 30 giorni                                 Dopo 60 giorni

  Angioma                                    Rimozione dei punti

Dopo 30 giorni                                 Dopo 60 giorni

                 CAPITOLO 3                                        9
QIJPH - 2019, Volume 8, Number 4

            ITALIAN JOURNAL OF PUBLIC HEALTH

           SCC                                         Rimozione dei punti

      Dopo 30 giorni                                     Dopo 60 giorni

     Neurofibromatosi                                  Rimozione dei punti

      Dopo 30 giorni                                     Dopo 60 giorni

10                                        CAPITOLO 3
QIJPH - 2019, Volume 8, Number 4

                  ITALIAN JOURNAL OF PUBLIC HEALTH

Studio clinico di un nuovo preparato a
base di H2O2 e acido ialuronico
Anna Cammisa, Silvio Masci

SCOPO                                                 RISULTATI

      Scopo dello studio è stato quello di valutare         Un solo paziente abbandona lo studio per
l'efficacia dell'asso­ciazione di un gel a base di    l'insorgenza di intenso bruciore. Nelle follicoliti
acido ialuronico con perossido di idrogeno in         i risultati sono stati giudicati buoni in 10 pazienti
pazienti affetti da follicolite, perionissi, ferite   ed ottimi negli altri 10. Analoga efficacia è stata
ed ulcere ad eziologia post traumatica, venosa        riscontrata nella perionissi con esiti buoni in
e diabetica.                                          quattro pazienti ed ottimi in 16; i risultati sono
                                                      stati buoni nelle ferite e nelle ulcere post-
                                                      traumatiche; nelle forme ulcerati­ve ad eziologia
METODI                                                venosa e diabetica ha dato scarsi risultati in
                                                      relazione alla risoluzione e alla cicatrizzazione
     Lo studio è stato condotto su 80 pazienti        mantenendone peraltro una buona deter­sione.
divisi in quattro gruppi omogenei per patologia       La tollerabilità si è dimostrata ottima (alcuni
(perionissi, follicoliti, ferite ed ulcere). I        pazienti hanno lamen­      tato esclusivamente una
pazienti sono stati trattati quotidianamente e        incostante sensazione di bruciore). Non sono
fino a due volte al giorno con il gel a base          stati registrati effetti collaterali.
di acido ialuronico associato a perossido di
idrogeno per un periodo di circa 20 giorni
(le ulcere e le ferite sono state valutate anche      CONCLUSIONI
oltre il ventesimo giorno). Una concomitan­
te terapia antibiotica sistemica si è resa                 Il gel a base di acido ialuronico associato
necessaria in tre pazienti affetti da ulcere ed in    a perossido di idrogeno si è dimostrato
due pazienti con perionissi; a quattro pazienti       ottimo in tollerabilità ed efficace nell'indurre
affetti da perionissi è stata aggiunta terapia        il miglioramento - fino a guarigione - delle
antibiotica locale.                                   perionissi, delle follicoliti, delle ferite e delle
     L'efficacia clinica è stata valutata             ulcere post-traumatiche; nelle forme ulcerative
osservazionalmente secondo quattro categorie          ad eziologia venosa e diabetica ha garantito
si giudizio: scarsa, moderata, buona, ottima.         una buona detersione grazie al potere
                                                      batteriostatico.

                                         CAPITOLO 4                                                  11
QIJPH - 2019, Volume 8, Number 4

                  ITALIAN JOURNAL OF PUBLIC HEALTH

Studio clinico sull'efficacia di un
nuovo preparato a base di H2O2 e acido
ialuronico nel trattamento delle piccole
ustioni
Anna Cammisa, Silvio Masci

     Sono stati arruolati sequenzialmente 40          terapie antibio­tiche aggiuntive.
pazienti in un unico gruppo ambulatoriale, non             La riepitelizzazione e cicatrizzazione è stata
controllato, sottoposti a trattamento con un          giudicata eccellente nel 70% dei casi e buona
gel a base di perossido di idrogeno (al 3%) ed        nel 30%, ed il gradimento del trattamento da
acido ialuronico. La composizione del gruppo          parte dei pazienti è stato eccellente nel 90%
di trattati era di 29 femmine e 11 maschi, di età     dei casi e buono nel restante 10%. L'unico
media 42 anni (range 3-76), con piccole ustioni       effetto collaterale lamentato è stato il bruciore
termiche, 5 pazienti sono stati trattati in seguito   presente in forma lieve in 13 pazienti (32,5%),
a crioterapia. Le lesioni di 1 ° e 2° grado (20% 1    mentre solo 3 pazienti (7,5%) hanno lamentato
° grado e 80% di 2° grado), avevano dimensioni        un forte bruciore, tutti questi hanno indicato la
classificate come inferiori a 9 cm2 (92,5%) o         persistenza del sintomo solo durante le prime
comprese tra 10 e 25 cm2 (7,5%).                      applicazioni del gel.
     La terapia prescritta prevedeva l'applicazione        Riteniamo che dai dati emersi dallo studio,
in due sonuninistrazioni giornaliere del gel ed       si possa affermare l'ottima tollerabilità ed
al bisogno poteva essere aggiunta una terapia         efficacia del prodotto sulle ustioni superficiali
antibiotica.                                          di 1° e 2° grado sia in termini di tempo
     Tutti i pazienti hanno raggiunto la              di cicatrizzazione che d'assenza d'infezioni
cicatrizzazione delle lesioni in un tempo medio       concomitanti.
di 6,3 giorni (range 2-10) senza la necessità di

  12                                            CAPITOLO 5