SISTEMA DI CONTROLLO 3CARS - 3CARS CONTROL SYSTEM Cold Car Controller Advanced Refrigeration System
SISTEMA DI CONTROLLO 3CARS                                                                    FACILITÀ D’UTILIZZO E SICUREZZA
                                   3CARS CONTROL SYSTEM                                                                             EASY TO USE AND SAFE

    Display con tastiera montato all’esterno              Display: Keypad mounted outside the         Informazioni a display:                        Info on display:
    della carrozzeria, evidenzia la temperatu-            body, indicates the operating tempera-
                                                                                                      • Temperatura interna                          • Inner temperature
    ra d’esercizio ed è l’interfaccia del sistema         ture and system interface for controlling
    per il controllo delle funzioni della stessa.         functions of the body.                      • Temperature delle singole piastre            • Temperature of each eutectic plate
                                                                                                      • Pressioni impianto (alta e bassa)            • Pressures of plant (high and low)
    Facilità di utilizzo e sicurezza per agevo-           Ease of use: Assists the user in the con-   • Temperatura condensatore (ingresso           • Condenser’s temperature (inlet and outlet)
    lare l’utente nel controllo di avviamento,            trol of starting, stopping, running and       e uscita)                                    • Residual cold during deliveries
    arresto, conduzione e manutenzione del-               maintaining of the truck body.              • Residuo carica freddo durante consegne       • Total time charge
    la carrozzeria.
                                                          Energy Saving: Intelligent Electronics      • Tempo di carica totale                       • Total on road time
    Risparmio Energetico: l’elettronica in-               helps scheduling to have a daily energy     • Tempo di strada totale                       • Time of next service of. refrigeration unit
    telligente è programmata per avere un                 saving of 30% due to an optimized tem-      • Tempo previsto per prossima
    risparmio energetico quotidiano del 30%               perature control.                             manutenzione gruppo frigo
    derivato da un ottimizzato controllo delle
    temperature.                                          Service and maintenance: Using data
                                                          down loaded, Cold Car is able to re-
                                                                                                      Sicurezza e controllo:                         Safety and control:
    Assistenza e manutenzione: tramite lo                 motely read all operating parameters of
    scarico dei dati il service Cold Car è in             the body for a three week time period.      • Partenza ad impulsi compressore              • Impulse start of the compressor
    grado di leggere in remoto tutti i parame-                                                          (protezione da colpi di liquido)               (protection from liquid)
    tri di utilizzo della carrozzeria delle ulti-                                                     • Segnalazione porta aperta                    • Door open Indicators
    me tre settimane di lavoro.                                                                       • Riallineamento delle fasi di rete            • Control of phase sequences
                                                                                                      • Controllo senso di rotazione ventola         • Control of the direction of the electro-fan
                                                                                                      • Controllo tensioni in entrata e protezione   • Control of in and out voltage and
                                                                                                        impianto da tensione bassa/alta                protection from high/low voltage
                                                    -34,4°C                                           • Segnalazione impianto da sbrinare            • Defrost needed
                                              CHARGE READY                                            • Segnalazione eventuale guasti                • Indication of damages

                                                                       3CARS
2                                                                                                                                                                                                    3
SISTEMA DI CONTROLLO 3CARS - 3CARS CONTROL SYSTEM Cold Car Controller Advanced Refrigeration System
ASSISTENZA E MANUTENZIONE                                                                                 RISPARMIO ENERGETICO
                               SERVICE AND MAINTENANCE                                                                                           ENERGY SAVING

    Assistenza                                      Service                                         ECO CARES                                                ECO CARES
    La centralina registra sulla sua memoria        The device records on its internal memory       Attraverso l’analisi della carrozzeria, vengo-           Through the analysis of the body, some pa-
    interna più di 40 parametri con cadenza 2       more than 40 parameters, every 2 minute         no studiati alcuni paramentri che consen-                rameters are studied to allow a further ener-
    minuti per 15 giorni consecutivi.               for 15 consecutive days.                                                                                 gy saving. The management of the double-
                                                                                                    tono di avere un ulteriore risparmio ener-
    In questo modo tramite la SD card in do-        In this way, via the supplied SD card, you
                                                                                                    getico: la gestione della ventola a doppia               speed fan, optimized management of the
    tazione è possibile scaricare i dati relativi   can download data from the body and
                                                    send by email to Cold Car, where the data       velocità, la gestione ottimizzata delle resi-            heaters of the side doors, and the thermostat
    alla carrozzeria ed inviarli via mail a Cold
    Car, che potrà analizzarli ed eventualmen-      is analyzed. Issues that are evident from the   stenze degli sportelli e il settaggio del termo-         settings, allows control that can mean an sa-
    te intervenire a distanza modificando i pa-     data can then be corrected by changing the      stato, permettono di arrivare ad un risparmio            ving energy by about 30%.
    rametri di funzionamento.                       parameters and functional characteristics.      energetico del 30% circa.

                                                                                                                                                        RISPARMIO ANNUO
                        CARROZZERIA                                                                                    € 1.400                          YEARLY SAVINGS

                        BODY                                                                                           € 1.200

                                                                                                                       € 1.000                  € 372
                                                                                                                       €     800
       INVIO DATI EMAIL                                              INVIO DATI EMAIL                                  €     600                                         € 1.209
       SEND DATA BY E-MAIL                                           SEND DATA BY E-MAIL                               €     400                € 837
                                                                                                                       €     200

                       NUOVI PARAMETRI                                                                                 €        -
                       NEW PARAMETERS                                                                                                    3CARS + ECO CARES           STANDARD BODY

                                                                                                                   *dati riferiti ad una carrozzeria           ** data referred to a 8 side door
                                                                                                                    a piastre eutettiche, 8 sportelli             body with eutectic plates
                                                                                                                    60q. – costo 0,15€/kwh

4                                                                                                                                                                                                            5
SISTEMA DI CONTROLLO 3CARS - 3CARS CONTROL SYSTEM Cold Car Controller Advanced Refrigeration System
CONFRONTO CONSUMI                                                                              GESTIONE DATI
                      COMPARISON OF CONSUMPTION                                                                      DATA MANAGEMENT

                                                    SISTEMA 3CARS
                                                                                   Capture Light                                     Capture Light
                                                    + ECO CARE*     TRADIZIONALE   Tramite un programma personalizzato sarà          Using our custom software you can view and
                                                    3CARS SYSTEM    STANDARD       possibile visualizzare lo storico dei dati del-   print the historical data of the body (internal
                                                    + ECO CARE*
                                                                                   la carrozzeria: temperatura interna - tempe-      temperature - temperature of plates - positive
          COLLEGAMENTO RETE                                                        ratura piastre - temperatura vano positivo        compartment temperature, duration of door
                                                        13,5 h         13,5 h
          CONNECTION TO THE MAINS                                                  - tempo apertura porte - tempo funziona-          openings, compressor operating time).
                                                                                   mento compressore.
          TEMPERATURA PARTENZA
          AMBIENTE
                                                        -18 C°         -18 C°
          STARTING TEMPERATURE IN
          THE BODY

          TEMPERATURA PARTENZA
          PIASTRE
                                                        -25 C°         -25 C°
          STARTING TEMPERATURE OF
          THE PLATES

          TEMPERATURA RAGGIUNTA
          AMBIENTE
                                                        -33 C°         -33 C°
          OPTIMUM COMPARTMENT
          TEMPERATURE

          TEMPO RAGGIUNGIMENTO
          TEMPERATURA AMBIENTE
                                                         7H            8,5 H
          TIME TO REACH
          TEMPERATURE

          CONSUMO KWH
          KWH CONSUMPTION
                                                       18 KW           26 KW           Display in cabina con stampante               In cabin devise with printer
                                                                                       Tramite un display supplementare posi-        Additional information can be read
                                                                                       zionato in cabina sarà possibile visualiz-    directly on a display in the cabin. An
    * Controllo intelligente resistenze sportelli
                                                                                       zare le stesse informazioni che appaio-       optional portable printer is available to
       e velocità ventola condensatore                                                 no sul display esterno. Inoltre mediante      print historical data based on the de-
    * Intelligent control of door heaters
                                                                                       l’aggiunta di una stampante portatile, si     sired frequency.
     and electro-fan speed                                                             potrà stampare lo storico dei dati in base    Total daily capacity 62 minutes.
                                                                                       alla cadenza desiderata. (giornaliero o
6                                                                                      totale - da 2 min. a 1 ora)                                                                     7
TIME CHARGE                                                                                    FUNZIONAMENTO

    TIME CHARGE                                     TIME CHARGE
                                                                                                  FASE              DESCRIZIONE                                VANTAGGI
    È un sistema evoluto per la gestione ottimale   Is an advanced system for optimal manage-
    della carrozzeria e del risparmio energetico,   ment of the body and energy conservation                        Permette di impostare l’ora e il giorno    Personalizzazione della pianificazione

                                                                                                   PROGRAMMAZIONE
    garantendo minori consumi e costi ridotti.      Proper application will ensure lower energy                     della settimana in cui la carrozzeria      in base alle singole esigenze (es. stand-
    Questo sistema garantice il massimo ri-         consumption and reduced costs.                                  deve essere in temperatura (program-       by della temperatura a -23 durante
    sparmio energetico e la massima presta-         This system enables conservation through                        mazione settimanale).                      il week-end e pronto carica il lunedì
    zione dell’impianto firgorifero attraverso      the “Ready Charge Planning Program” and                                                                    mattina).
    una programmazione del pronto carica,           automated control system. Automated start
    una gestione automatica dei tempi di par-       times and daily analysis of the conditions
    tenza dell’impianto e un’analisi quotidiana     of the body will ensure the preservation of                     Il sistema provvederà a mantenere la       • Il consumo energetico durante la

                                                                                                   MANTENIMENTO
    delle condizioni della carrozzeria.             loaded product. The program is designed                         temperatura interna a -23C°, in modo         fase di stand by è quasi nullo.
    Tutto ciò permetterà di conservare la mer-      to manage routine daily use as well as the                      da conservare il prodotto durante la       • Ridotto uso del compressore con
    ce all’interno della carrozzeria, limitare      ability to monitor the compressor on non-                       notte.                                       conseguente minore usura.
    l’utilizzo del compressore, riducendo così      working days and weekends. Automated
    i costi di manutenzione, stabilire I giorni     limiting of the compressor’s run times will
    non lavorativi e I week-end.                    reduce maintenance costs.
                                                                                                                    Il sistema 12 ore prima del pronto ca-     Conoscere esattamente il tempo ne-
                                                                                                                    rica esegue un test di funzionamento       cessario al raggiungimento della tem-
     CARATTERISTICHE                                FEATURES                                                        che permette di determinare il tempo       peratura tenendo conto delle effettive

                                                                                                   TEST
     • Gestione automatica dei tempi di carica      • Automatic management of charging time                         necessario al raggiungimento della         condizioni d’uso della carrozzeria
     • Analisi quotidiana condizioni carrozzeria    • Body conditions daily analysis                                temperatura (da -23 a -35).                (temperatura esterna, livello brina, tem-
                                                                                                                                                               peratura della merce, etc...).
     • Programmazione giornaliera                   • Daily planning
     • Conservazione della merce all’interno        • Preservation of Goods inside the body
       carrozzeria                                                                                                  All’ora impostata la carrozzeria sarà      Carrozzeria sempre in temperatura

                                                                                                   PRONTO CARICA
                                                                                                                    in temperatura. Nel caso in cui dopo       all’ora programmata.
     VANTAGGI                                       ADVANTAGES                                                      3 ore la carrozzeria non venisse mo-       Nessun spreco di energia in caso di
     • Minor utilizzo del compressore               • Less use of the compressor                                    vimentata, la temperatura interna si       giorni festivi infrasettimanali o assenza
     • Minor costi di manutenzione                  • Lower maintenance costs                                       riporterà alla fase di stand by di -23 e   dell’autista.
     • Opzione week end e giorni non lavorativi     • Automatic option for week end and no                          ripartirà la programmazione prevista
       in automatico                                  working days                                                  per il giorno successivo.
     • Minori consumi e conseguente inquinamento    • Lower consumption and less pollution
8                                                                                                                                                                                                          9
FEATURES                                                   FUNZIONAMENTO STANDARD
                                                                                                                  STANDARD OPERATION

     PHASE           DESCRIPTION                                ADVANTAGES

                     Allows you to set the time and day of      Customizing the programming based
      PROGRAMMING

                     week in which the body must be in          on individual needs (i.e. stand-by tem-
                     temperature (weekly schedule).             perature to -23°C during the week-
                                                                end and Ready Charge on Monday
                                                                morning).

                     The system will maintain the inner tem-    • The power consumption during
      MAINTENANCE

                     perature at-23°C, to maintain the prod-      standby is almost nil.
                     uct’s temperature during the night.        • Reduced use of the compressor
                                                                  resulting in less wear.

                                                                                                           FUNZIONAMENTO CON TIME CHARGE
                     The system 12 hours before the Ready       Knowing the exact time to the reach            OPERATION WITH TIME CHARGE
                     Charge performs a functional test for      the correct temperature taking into ac-
                     determining the time required to reach     count the real conditions of use of the
      TEST

                     the correct temperature (from -23°C to     body (external temperature, frost level,
                     -35°C).                                    temperature of the goods, etc ...).

                     At the set time the body will be at the    Body always at the right temperature
      READY CHARGE

                     right temperature. In the event that the   in the scheduled time. No waste of
                     body will not be moved in the next 3       energy in case of midweek holidays or
                     hours, the inner temperature will go       absence of the driver.
                     back to the stage of stand by -23°C and
                     restart the planning for the next day.

10                                                                                                                                          11
ENERGY SAVE                        DATA MANAGEMENT

TIME CHARGE                           CAPTURE LIGHT

                       -34,4°C
                     CHARGE READY

                                          3CARS

                                            PRINTER +
 ECO CARES
                                          INCAB DISPLAY

             Tel. +39 0142 400611
             Fax +39 0142 462001
             Strada Paniate, 1

                                                          www.creatio.it